{"product_id":"16-channel-ac-digital-input-module-yokogawa-adv141-p53","title":"16 Channel AC Digital Input Module | Yokogawa ADV141-P53","description":"\u003ch2\u003eYokogawa ADV141-P53 Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-voltage 100 to 120 VAC discrete signal acquisition in CENTUM VP control systems, the \u003cstrong\u003eYokogawa ADV141-P53\u003c\/strong\u003e (\u003cstrong\u003eADV141\u003c\/strong\u003e Digital Input Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCode \/ Suffix\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Implication\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eADV141\u003c\/td\u003e\n\u003ctd\u003eBase Hardware Model\u003c\/td\u003e\n\u003ctd\u003e16-channel isolated digital input module (100 to 120 VAC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-P\u003c\/td\u003e\n\u003ctd\u003ePushbutton Input Option\u003c\/td\u003e\n\u003ctd\u003eEnables direct pushbutton edge detection and contact monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eDisplay \u0026amp; Non-Ex Type\u003c\/td\u003e\n\u003ctd\u003eIncludes front-panel status LEDs; non-explosion-proof specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eEnvironmental \u0026amp; Temp Option\u003c\/td\u003e\n\u003ctd\u003eIncludes ISA Standard G3 conformal coating and extended operating range (-20 to 70 deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV141-P53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.40 kg Net \/ 2.0 kg Shipping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Yokogawa CENTUM VP rack-mount I\/O footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e330 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 discrete inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003e100 to 120 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput ON Voltage Range\u003c\/td\u003e\n\u003ctd\u003e85 to 132 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput OFF Voltage\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 30 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e4.1 mA +\/- 20% per channel at nominal voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Allowable Input Voltage\u003c\/td\u003e\n\u003ctd\u003e150 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Withstand\u003c\/td\u003e\n\u003ctd\u003e2000 VAC for 1 minute (signal to system logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 8 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal Coating\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Isolation Interface\u003c\/h3\u003e\n\u003cp\u003eThe module processes discrete high-voltage field contact states across 16 isolated channels, channeling field data straight to node controllers while preventing common-mode ground loops. Incorporating channel-to-system optical isolation up to 2000 VAC withstand rating, the hardware decouples plant-floor electrical transients from sensitive backplane logic. Designed for seamless execution within process control systems, the unit maintains signal integrity across severe industrial environments through ISA Standard G3 environmental protection.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the ADV141-P53 module allow live hot-swapping during system operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes. You can remove and replace an ADV141-P53 module online while the backplane remains powered, preserving continuous execution across adjacent I\/O slots.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle signal isolation between field wiring and system backplane?\u003c\/p\u003e\n\u003cp\u003eA: The module uses galvanic and optical isolation barriers that withstand 2000 VAC for one minute, isolating field-side AC noise and ground potential differences from system logic.\u003c\/p\u003e\n\u003cp\u003eQ: What environmental conditions does the \"-P53\" suffix configuration protect against?\u003c\/p\u003e\n\u003cp\u003eA: The suffix designates an extended operating temperature range of -20 to 70 deg C alongside ISA Standard G3 conformal coating, which shields internal circuitry from corrosive atmospheric contaminants.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting and Latch Verification:\u003c\/strong\u003e Slide the module firmly into its assigned slot on the node unit baseplate until top and bottom retention mechanism levers lock completely into place.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding and Shielding Protocols:\u003c\/strong\u003e Connect cabinet structure earth to the primary copper ground bus before applying field voltage. Ensure field wiring metal conduits terminate at the designated cabinet entry ground plate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Field Wiring Separation:\u003c\/strong\u003e Route 100-120 VAC input signal cables through dedicated wire troughs strictly separated from low-voltage DC lines and high-speed communication buses to suppress capacitive coupling.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43859803439194,"sku":"ADV141-P53","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/171._f5b5ba0e-1503-410f-954e-086113a74397.jpg?v=1787024907","url":"https:\/\/www.spareoil.com\/ar\/products\/16-channel-ac-digital-input-module-yokogawa-adv141-p53","provider":"SpareOil Automation","version":"1.0","type":"link"}