{"product_id":"32-channel-digital-input-card-yokogawa-adv151-e50-d5a00","title":"32-Channel Digital Input Card | Yokogawa ADV151-E50\/D5A00","description":"\u003ch2\u003eYokogawa ADV151-E50\/D5A00 FIO Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-density status signal acquisition in CENTUM VP distributed control systems, the \u003cstrong\u003eYokogawa ADV151-E50\/D5A00\u003c\/strong\u003e (\u003cstrong\u003eADV151\u003c\/strong\u003e Digital Input Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe ADV151 series utilizes specific ordering and suffix codes to define hardware capability, sequence-of-events recording, and physical interface connections:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model (ADV151):\u003c\/strong\u003e Designates a 32-channel, 24 VDC isolated digital input module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSOE Suffix (-E):\u003c\/strong\u003e Identifies built-in Sequence of Events (SOE) capture capability for precise time-stamping of status transitions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Suffix (5):\u003c\/strong\u003e Establishes compliance with ISA G3 corrosion specifications, enabling operation in harsh environments from -20 to 70 deg C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExplosion Protection Suffix (0):\u003c\/strong\u003e Indicates a standard design lacking intrinsic safety explosion protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOption Code (\/D5A00):\u003c\/strong\u003e Establishes integration with a dedicated KS Cable Interface Adapter configured for 32-channel digital connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV151-E50\/D5A00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg (1.5 kg shipping weight including adapter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Yokogawa FIO module slot dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e500 mA (at 5 V DC backplane power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e32 status inputs (isolated in groups of 16)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput ON \/ OFF Voltage\u003c\/td\u003e\n\u003ctd\u003eON: 18 to 26.4 VDC, OFF: less than or equal to 5.0 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e4.1 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e2 kV AC system-to-input for 1 minute; 500 VAC between common groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Diagnostics\u003c\/h3\u003e\n\u003cp\u003eThe digital input module provides robust electrical isolation to protect internal control logic, featuring a 2 kV AC system-to-input isolation barrier alongside a 500 VAC barrier between the two 16-channel common groups. This grouped isolation architecture prevents ground loop currents from circulating between separate field power grids. For diagnostic precision, the SOE capture circuitry records status transitions with high temporal resolution, registering fast-acting pushbuttons and process switches with a hardware response time of less than or equal to 8 ms.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is the common return path wired, and does it support mixed voltage sources?\u003c\/p\u003e\n\u003cp\u003eA: The 32 channels are isolated in two groups of 16. Each 16-channel group shares a common return path, meaning you must reference all 24 VDC signals within a single group to the same electrical polarity.\u003c\/p\u003e\n\u003cp\u003eQ: Can the \/D5A00 option code be field-retrofitted or replaced with pressure clamp terminals?\u003c\/p\u003e\n\u003cp\u003eA: The \/D5A00 option configures the card with a dedicated KS Cable Interface Adapter at the factory. Converting to standard pressure clamp terminals requires replacing the front connector block assembly with a compatible terminal block model.\u003c\/p\u003e\n\u003cp\u003eQ: Is this card hot-swappable in a dual-redundant configuration?\u003c\/p\u003e\n\u003cp\u003eA: Yes. When you configure two ADV151 modules in adjacent slots as a dual-redundant pair, you can replace a failed card while the redundant partner continues scanning the field status inputs.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterface Cable Routing:\u003c\/strong\u003e Route the KS interface cable through separate, grounded metallic wiring ducts to shield the 24 VDC digital signals from nearby high-voltage AC motor or drive cabling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabinet Grounding:\u003c\/strong\u003e Ensure that the DIN rail or rack subplate maintains a low-resistance connection to the master instrument ground to optimize the 2 kV AC galvanic isolation performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eG3 Environment Management:\u003c\/strong\u003e Keep the system cabinet doors closed and maintain positive cabinet pressure in process environments to preserve the ISA G3 conformal coating on the internal circuitry.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient Suppression:\u003c\/strong\u003e Install external suppression diodes across inductive field loads (such as interposing relays or solenoids) that share field power wiring with the input channels to block inductive voltage spikes.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43665143627866,"sku":"ADV151-E50\/D5A00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/463_9535b19b-8530-421a-887d-cd834f181fa3.jpg?v=1784183319","url":"https:\/\/www.spareoil.com\/ar\/products\/32-channel-digital-input-card-yokogawa-adv151-e50-d5a00","provider":"SpareOil Automation","version":"1.0","type":"link"}