{"product_id":"32-channel-input-module-yokogawa-adv151-p00-s2-centum-vp","title":"32-Channel Input Module | Yokogawa ADV151-P00 S2 CENTUM VP","description":"\u003ch2\u003eYokogawa ADV151-P00 S2 Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for discrete signal acquisition in industrial control systems, the \u003cstrong\u003eYokogawa ADV151-P00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eADV151\u003c\/strong\u003e Digital Input Module, provides direct physical\/electrical execution to monitor status inputs from field contacts. The hardware interfaces directly with field control stations to process isolated ON\/OFF state data without risking backplane damage from external voltage surges.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eADV151\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module (32-channel, 24 VDC, Isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-P\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSuffix Code\u003c\/td\u003e\n\u003ctd\u003eWith pushbutton input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSuffix Code\u003c\/td\u003e\n\u003ctd\u003eWithout status display; with explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSuffix Code\u003c\/td\u003e\n\u003ctd\u003eBasic type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV151-P00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e10.7 cm x 13.0 cm x 3.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e~500 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e32 isolated digital inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (sink\/source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Allowable Input Voltage\u003c\/td\u003e\n\u003ctd\u003e30.0 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput ON Voltage\u003c\/td\u003e\n\u003ctd\u003e18 to 26.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput OFF Voltage\u003c\/td\u003e\n\u003ctd\u003eLess than or equal to 5.0 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e~4.1 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Response Time\u003c\/td\u003e\n\u003ctd\u003e8 ms or less (for status input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePushbutton Detection\u003c\/td\u003e\n\u003ctd\u003eMinimum ON time: 20 ms; Maximum cycle: 25 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e2 kV AC (input-to-system, 1 min); 500 VAC (between commons, every 16 channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP, ProSafe-RS, CS 3000 systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe module contains isolated hardware circuitry divided into separate blocks to prevent electrical interference from compromising signal validity. It enforces strict galvanic separation with an input-to-system isolation limit of 2 kV AC and an independent 500 VAC isolation barrier between the common returns of each 16-channel group. This dual-layer isolation topology blocks common-mode noise and ground loop currents common in dense instrument wiring networks. The internal logic processes incoming 24 VDC pulses using discrete input filtering, filtering out contact bounce while capturing rapid status deviations from safety interlocks, limit switches, and physical operator interfaces.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the functional limitations when utilizing the hot-swap capability of this module?\u003c\/p\u003e\n\u003cp\u003eA: Engineers can replace the module online without shutting down the node backplane. However, during the physical swap interval, input data processing for all 32 channels halts instantly, meaning that the host controller will retain the last known valid state or transition to a predefined fault state depending on system software configuration.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module differentiate standard status inputs from pushbutton inputs based on the \"-P\" suffix specification?\u003c\/p\u003e\n\u003cp\u003eA: The configuration utilizes a dedicated hardware circuit designed to detect rapid transient closures. It guarantees the capture of short-duration pulses with a minimum ON time of 20 ms and supports pulse repetition frequencies up to a maximum cycle speed of 25 Hz.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Termination:\u003c\/strong\u003e Connect field loop conductors via the designated pressure clamp terminal block or a compatible MIL connector interface cable. Verify that all terminal screws match the torque ratings defined by the cabinet housing specifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding Regimen:\u003c\/strong\u003e Terminate all external digital signal cable shields at a single ground bus bar within the control enclosure. Maintain continuous separation between instrument ground networks and noisy power grounds to prevent high-frequency noise injection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Engagement:\u003c\/strong\u003e Align the alignment pins on the back of the module with the slot receptors on the field control unit node. Push the hardware component into place until the locking tabs latch completely, securing physical contact against industrial vibration vectors.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43667594281050,"sku":"ADV151-P00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/571..jpg?v=1784252384","url":"https:\/\/www.spareoil.com\/ar\/products\/32-channel-input-module-yokogawa-adv151-p00-s2-centum-vp","provider":"SpareOil Automation","version":"1.0","type":"link"}