{"product_id":"330104-00-23-10-02-00-3300-xl-8-mm-proximity-probes-bently-nevada","title":"330104-00-23-10-02-00 3300 XL 8 mm Proximity Probes | Bently Nevada","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330104-00-23-10-02-00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e330104\u003c\/strong\u003e Proximity Probe, operates as a dedicated hardware component for non-contacting displacement and vibration measurements within 3300 XL Proximity Transducer System platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330104\u003c\/strong\u003e: Base model number for 3300 XL 8 mm proximity probe with M10 x 1 threads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00\u003c\/strong\u003e: Unthreaded Length Option (00 = 0 mm).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-23\u003c\/strong\u003e: Overall Case Length Option (23 = 230 mm).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-10\u003c\/strong\u003e: Total Length Option (10 = 1.0 metre \/ 3.3 feet).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-02\u003c\/strong\u003e: Connector and Cable Type Option (02 = Miniature coaxial ClickLoc connector with connector protector, standard cable).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00\u003c\/strong\u003e: Agency Approval Option (00 = Not required).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330104-00-23-10-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eU.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.323 kg nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e8 mm probe tip diameter, 230 mm case length, 1.0 m total length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eConsumes power from external Proximitor Sensor loop (-17.5 VDC to -26 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e2.0 mm (80 mils) nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Factor\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) when paired with compatible 3300 XL Proximitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector with connector protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Configuration\u003c\/td\u003e\n\u003ctd\u003eStandard coaxial layout with integrated fluid barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Gap Voltage Validation\u003c\/h3\u003e\n\u003cp\u003eThe 330104-00-23-10-02-00 transducer acts via high-frequency eddy currents generated at the 8 mm tip to implement eddy-current probe scaling against a conductive shaft target. Accurate signal conversion necessitates a specific calibration curve matched to the material composition of the rotor dynamics target. During loop commissioning, field engineering requires rigorous gap voltage validation across the measuring path. Adjusting the probe's mechanical depth to register precise -10 VDC targets positions the hardware at the linear midpoint of its displacement range. This setting is required to isolate dynamic shaft movement while ensuring maximum cross-talk suppression between individual adjacent sensors monitoring the same machinery shaft.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does a modification or extension of the 1.0 metre total probe length impact system accuracy?\u003c\/p\u003e\n\u003cp\u003eA: The probe internal coil and cable length are tuned to match specific electrical parameters. Modifying the 1.0 metre physical line length or pairing it with an uncalibrated extension cable disrupts the total loop impedance, degrading the scale factor linearity and shifting the baseline gap voltage.\u003c\/p\u003e\n\u003cp\u003eQ: What protection is provided by the miniature coaxial ClickLoc connector protector assembly?\u003c\/p\u003e\n\u003cp\u003eA: The connector protector isolates the coaxial physical connection from external conductive paths and fluid tracking. This mechanism prevents the signal from grounding against metallic conduits or machinery casings, which would cause an absolute loss of the vibration output signal.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Mount Setup\u003c\/strong\u003e: Insert the probe case into the threaded M10 x 1 mounting bore. Hand-rotate the assembly until the tip is near the target, ensuring no direct impact occurs with the shaft face.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Voltage Adjustment\u003c\/strong\u003e: Connect a digital multimeter to the Proximitor sensor output terminals. Adjust the probe position within the threads until the recorded reading stabilizes at the standard -10 VDC target voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocknut Mechanical Securing\u003c\/strong\u003e: Secure the probe case in place using the designated locknut. Verify the output voltage does not drift away from the -10 VDC specification during final torquing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoaxial Routing Limitations\u003c\/strong\u003e: Route the standard cable through a dedicated, grounded metal conduit. Ensure the routing preserves a minimum static bend radius of 25.4 mm (1.0 inch) to prevent damage to the internal core shielding.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43604597997658,"sku":"330104-00-23-10-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/330104-00-08-05-02-00_9d27224d-f90b-446a-b53f-6882b2b02f33.png?v=1783325054","url":"https:\/\/www.spareoil.com\/ar\/products\/330104-00-23-10-02-00-3300-xl-8-mm-proximity-probes-bently-nevada","provider":"SpareOil Automation","version":"1.0","type":"link"}