{"product_id":"3636r-triconex-tricon-3000-series-relay-output-module","title":"3636R Triconex Tricon 3000 Series Relay Output Module","description":"\u003ch2\u003eTRICONEX 3636R Relay Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for providing fault-tolerant relay outputs to drive actuators such as valves, pumps, alarms, and trip relays in Tricon 3000 Series SIS racks, the \u003cstrong\u003eTRICONEX 3636R\u003c\/strong\u003e (\u003cstrong\u003eTRICONEX 3636R\u003c\/strong\u003e Relay Output Module) provides direct physical\/electrical execution. This hardware subassembly transforms system command logic into binary contact states across isolated electrical paths. The module manages electrical power switching to field components via integrated mechanical relay matrices.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3636R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTRICONEX (Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg (Shipping weight 2.0 kg to 4.0 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e177.8 mm x 101.6 mm x 228.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e~6 W typical @ 5 VDC, 24 VDC backplane powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e32 isolated relay outputs (Non-commoned)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e125 VAC\/VDC maximum (Data variation: up to 250 VAC \/ 30 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Load\u003c\/td\u003e\n\u003ctd\u003e2 A maximum resistive per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Permissible Load\u003c\/td\u003e\n\u003ctd\u003e10 mA @ 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eLess than or equal to 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Rating\u003c\/td\u003e\n\u003ctd\u003e1500 VDC channel-to-backplane, 2.5 kV RMS channel-to-channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Certification\u003c\/td\u003e\n\u003ctd\u003eIEC 61508 SIL3, IEC 61511, UL Class I Div 2, ATEX Zone 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTriple Modular Redundancy \u0026amp; Fail-Safe State Execution\u003c\/h3\u003e\n\u003cp\u003eThe hardware uses a Triple Modular Redundancy (TMR) architecture with integrated voting logic to enforce systematic fail-safe state execution. Three fully distinct internal execution branches receive parallel digital output data across the TriBus backplane. The module translates this data through independent coils to drive a series of internal relay contacts configured in a hardware-based voting matrix. If a fault causes one execution branch to drift from the parallel status, the redundant paths ensure correct state continuity at the terminal block. Galvanic isolation up to 2.5 kV RMS between distinct channels prevents electrical anomalies from propagating across the module circuitry, forcing a predictable de-energized or safe position if internal diagnostic thresholds drop below minimum criteria.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How do the built-in diagnostics evaluate individual channel health during active field operations?\u003c\/p\u003e\n\u003cp\u003eA: The module runs continuous, non-disruptive per-channel monitoring circuits that check coil continuity and contact position health. If a discrepancy occurs between the intended TMR state and the physical relay feedback, the module lights the local FAULT LED indicator and reports the channel variance to the system controller logs.\u003c\/p\u003e\n\u003cp\u003eQ: What are the parameters for executing an online hot-swap without causing accidental contact actuation?\u003c\/p\u003e\n\u003cp\u003eA: Online hot-swap is supported directly within the chassis rack. Before extraction, verify that the adjacent or redundant module slot has taken over control. The physical backplane connectors allow live module removal and insertion without disrupting active field loop power or inducing spurious contact trips.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Earth Reference\u003c\/strong\u003e: Ensure that the single-slot rack chassis installation maintains solid electrical contact with the system enclosure ground bus. Proper grounding suppresses high-frequency electromagnetic interference from altering relay coil signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Wiring and Isolation\u003c\/strong\u003e: Run all field output wiring through dedicated terminal blocks, verifying that non-commoned paths remain physically separated. Route external lines away from high-voltage AC cables to limit signal noise coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Load Protection\u003c\/strong\u003e: Verify that the maximum switching current does not exceed 2 A resistive per channel. For highly inductive or capacitive external loads, install external suppression components to prevent contact pitting and prolong mechanical lifecycle parameters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Limits\u003c\/strong\u003e: For installations requiring compliance with ATEX Zone 2 or UL Class I Div 2 standards, verify that the module enclosure remains fully secured within the environmental protective housing to maintain local ignition boundaries.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":43723319148634,"sku":"3636R","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/165._938e33eb-d678-4041-8480-7cfa4d733c81.jpg?v=1784857732","url":"https:\/\/www.spareoil.com\/ar\/products\/3636r-triconex-tricon-3000-series-relay-output-module","provider":"SpareOil Automation","version":"1.0","type":"link"}