{"product_id":"3636t-triconex-tricon-3000-series-relay-output-module-32ch","title":"3636T Triconex Tricon 3000 Series Relay Output Module 32Ch","description":"\u003ch2\u003eTriconex 3636T Digital Relay Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for fault-tolerant discrete output signal execution in safety-critical loops, the \u003cstrong\u003eTriconex 3636T\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e3636T\u003c\/strong\u003e Digital Relay Output Module, operates as a dedicated hardware component for driving discrete field circuits within Tricon 3000 Series Safety Instrumented System (SIS) platforms. The hardware switches control signals through non-triplicated relay output configurations, supporting voltage limits up to 125 VAC\/VDC. Operating as the direct interface to final control elements, this physical module links backplane command states to external inductive relays, trip circuits, solenoids, and alarms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3636T (Part Number: 3000314-315 REV.E)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric - Triconex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.0 kg (Shipping weight) \/ 1.5 - 2.0 kg (Net module weight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e177.8 mm x 101.6 mm x 228.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e15 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e32 isolated digital outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e125 VAC\/VDC maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Load\u003c\/td\u003e\n\u003ctd\u003e2 A maximum per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArchitecture\u003c\/td\u003e\n\u003ctd\u003eTriple Modular Redundancy (TMR), 2-out-of-3 voting (Non-triplicated RO stage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Integrity Level\u003c\/td\u003e\n\u003ctd\u003eSIL3 capable (IEC 61508 \/ IEC 61511 compliance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoint Isolation\u003c\/td\u003e\n\u003ctd\u003e1900 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation (Backplane\/Field)\u003c\/td\u003e\n\u003ctd\u003e1500 VAC galvanic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5% - 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination Style\u003c\/td\u003e\n\u003ctd\u003eScrew-clamp terminals, accepts 12 - 22 AWG wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHigh Reliability Safety Control (SIS) Technical Attributes\u003c\/h3\u003e\n\u003cp\u003eThe unit functions in coordination with a Triple Modular Redundancy (TMR) 2oo3 architecture, ensuring internal diagnostic coverage and logic leg cross-checking before signal transmission. Galvanic isolation limits are enforced at 1500 VAC between the system backplane and the field termination lines, supplemented by an enhanced 1900 VDC point-to-point physical isolation threshold across individual output paths to counter voltage transients and field ground faults. Fail-safe state execution routines are integrated into the physical circuitry; upon verification of an unrecoverable internal logic deviation or communication drop, the designated outputs return immediately to a de-energized, safe state. High-density component layout maps 32 discrete output circuits into a single slot configuration, providing deterministic operation via TriStation software parameters.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the 3636T module handle heavy inductive loads up to the 125 VAC\/VDC maximum limit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The dry relay contacts withstand up to 2 A load current, but external flyback diodes or RC snubber circuits matched to the specific inductive load are mandatory. These external suppressors prevent contact arcing and protect the 1900 VDC point isolation layers from long-term breakdown.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the non-triplicated relay output structure diminish the system's active safety integrity?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The internal processing, logic voting, and diagnostic checks run within the fully redundant 2oo3 leg framework before driving the final output stage. The mechanical relays execute the resulting logic, and continuous self-test routines track circuit health to preserve the SIL3 safety integrity rating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Are there any specific physical or timing restrictions during an online hot-swap installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Online hot-swap is fully supported without interrupting the system process. The technician must completely insert the replacement unit into the adjacent slot and verify synchronization before the software watchdog timer expires to avert spurious diagnostic trips.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eField technicians must verify that all field terminations comply with specific industrial wiring protocols. All control loops must utilize 12 to 22 AWG copper conductors secured tightly into the terminal blocks. Maintain strict physical isolation barriers between low-voltage DC signals, 125 V operational loops, and high-voltage AC distribution infrastructure to eliminate electromagnetic coupling. Internal system grounding rails must terminate directly to the main plant instrumentation earth through a low-impedance connection, ensuring all shield drain wires are un-spliced and grounded at a single terminal node. Slide the hardware smoothly along the guide rails of the Tricon 3000 Series rack until the rear pins are completely seated within the backplane connector block. Tighten all mechanical retention screws to secure the module against operational ambient vibration. Prior to starting an online hot-swap procedure, use the TriStation diagnostic dashboard to confirm the redundant slot is active and free of pre-existing faults.\u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":43736419106906,"sku":"3636T","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/214._212cd1d7-713e-476a-a535-1b71fb98dcf7.jpg?v=1785123646","url":"https:\/\/www.spareoil.com\/ar\/products\/3636t-triconex-tricon-3000-series-relay-output-module-32ch","provider":"SpareOil Automation","version":"1.0","type":"link"}