{"product_id":"3bse008510r1-abb-do810-16-channel-digital-output-module","title":"ABB 3BSE008510R1 DO810 Digital Output Module","description":"\u003cp\u003eThe ABB DO810 (3BSE008510R1) is a 16-channel digital output module designed for the S800 I\/O system. This module provides reliable, high-side switching for 24 V d.c. applications, making it suitable for driving field devices such as relays, contactors, and indicator lamps within industrial control environments. The module features two isolated groups of eight channels, each equipped with process voltage supervision to ensure system integrity.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16-channel digital output configuration (24 V d.c. current sourcing).\u003c\/li\u003e\n\u003cli\u003eTwo isolated groups of eight channels, each with independent process voltage supervision.\u003c\/li\u003e\n\u003cli\u003eIntegrated Output Set to Predetermined state (OSP) functionality for safe-state management during communication loss.\u003c\/li\u003e\n\u003cli\u003eComprehensive protection: short-circuit to ground, short-circuit to 30 V, over-temperature, and over-voltage protection.\u003c\/li\u003e\n\u003cli\u003eChannel-specific status indication via LEDs.\u003c\/li\u003e\n\u003cli\u003eOptical isolation barrier between field and system signals.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBurner Management Systems (BMS) for sequential control of ignition devices and fuel valves.\u003c\/li\u003e\n\u003cli\u003ePump and compressor sequencing, including motor starter management.\u003c\/li\u003e\n\u003cli\u003eTurbine control auxiliaries, such as cooling fan and motorized valve control.\u003c\/li\u003e\n\u003cli\u003eSubstation automation for triggering circuit breakers and isolators.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDO810 (3BSE008510R1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003e24 V d.c. Current Sourcing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Continuous Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V a.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption (+5V ModuleBus)\u003c\/td\u003e\n\u003ctd\u003e80 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system is powered down before installing or removing the module from the S800 I\/O cluster.\u003c\/li\u003e\n\u003cli\u003eThe module should be mounted in a clean, dry environment protected from direct exposure to corrosive gases or excessive dust.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding practices are followed to maintain EMC immunity, particularly when handling inductive loads.\u003c\/li\u003e\n\u003cli\u003eUse shielded cables for field wiring to minimize EMI interference in high-noise industrial environments.\u003c\/li\u003e\n\u003cli\u003eVerify that the process voltage is within the specified 10-30 V d.c. range to prevent false supervision error signals.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the DO810?\u003c\/h3\u003e\u003cp\u003eThe DO810 acts as a digital interface between the control system (e.g., 800xA or Freelance) and field equipment, providing 16 channels of 24 V d.c. outputs for device control.\u003c\/p\u003e\u003ch3\u003eHow does the module handle communication errors?\u003c\/h3\u003e\u003cp\u003eThe module utilizes the OSP (Output Set to Predetermined) function, which allows outputs to transition to a predefined safe state if a communication fault or watchdog timeout occurs.\u003c\/p\u003e\u003ch3\u003eWhat protection features are included?\u003c\/h3\u003e\u003cp\u003eEach channel is protected against short circuits, over-temperature, and over-voltage conditions. Additionally, the module provides inductive load suppression to protect the internal high-side drivers.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44048449110106,"sku":"3BSE008510R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_240eb3db-449c-485c-9aaf-2a45f046f700.jpg?v=1789093149","url":"https:\/\/www.spareoil.com\/ar\/products\/3bse008510r1-abb-do810-16-channel-digital-output-module","provider":"SpareOil Automation","version":"1.0","type":"link"}