{"product_id":"allen-bradley-1756-a10xt-extreme-environment-chassis","title":"Allen-Bradley 1756-A10XT ControlLogix Extreme Environment 10-Slot Chassis","description":"\u003cp\u003eThe Allen-Bradley 1756-A10XT is a 10-slot backplane chassis engineered specifically for the ControlLogix XT (Extreme Environment) series. This ruggedized hardware provides a reliable mounting and communication foundation for processors, I\/O modules, and communication bridges in industrial applications subjected to harsh conditions, including corrosive atmospheres, extreme thermal cycling, and high levels of vibration.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRuggedized Design:\u003c\/strong\u003e Built to maintain electrical and structural integrity in environments where standard control hardware may experience premature failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtreme Environment (XT) Rating:\u003c\/strong\u003e Optimized for challenging industrial settings requiring high environmental resilience.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Resilience:\u003c\/strong\u003e Enhanced protection against electrostatic discharge, rated for 6 kV contact and 8 kV air discharge.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Tolerance:\u003c\/strong\u003e Operates reliably in non-condensing humidity levels between 5% and 95%.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Compatibility:\u003c\/strong\u003e Fully compatible with the standard Bulletin 1756 ControlLogix module ecosystem.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis chassis is ideal for deployment in critical infrastructure, chemical processing plants, and remote industrial sites where ambient conditions are severe. It is suitable for use in installations requiring Zone 2 hazardous area certification.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eControlLogix XT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlots\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eHorizontal (Rear panel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eConvection (Vertical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eESD Protection\u003c\/td\u003e\n\u003ctd\u003e6 kV contact \/ 8 kV air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd\u003eOpen-type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the chassis is mounted on a flat, rigid surface to minimize mechanical stress.\u003c\/li\u003e\n\u003cli\u003eMaintain proper vertical clearance to allow for effective convection cooling through the chassis backplane.\u003c\/li\u003e\n\u003cli\u003eWhen handling modules, observe standard ESD precautions to protect internal circuitry.\u003c\/li\u003e\n\u003cli\u003eVerify that all module connections are fully seated in the backplane connectors before applying power.\u003c\/li\u003e\n\u003cli\u003ePower down the system before inserting or removing any ControlLogix modules from the chassis slots.\u003c\/li\u003e\n\u003cli\u003eEnsure the environment remains within the specified temperature and humidity ranges to prevent condensation buildup within the chassis.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eIs the 1756-A10XT compatible with standard ControlLogix modules?\u003c\/h3\u003e\u003cp\u003eYes, the 1756-A10XT is designed to house standard 1756 ControlLogix modules while providing the added environmental protection required for XT-series applications.\u003c\/p\u003e\u003ch3\u003eWhat does the XT designation mean for this chassis?\u003c\/h3\u003e\u003cp\u003eThe XT designation indicates that the unit is built to withstand harsher environmental factors than standard chassis, such as corrosive gases and wider temperature fluctuations, making it suitable for demanding industrial deployments.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43996076572762,"sku":"1756-A10XT","price":56.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_bd43f063-e6b6-40a2-8d1e-4d2df7e7e99e.jpg?v=1788306734","url":"https:\/\/www.spareoil.com\/ar\/products\/allen-bradley-1756-a10xt-extreme-environment-chassis","provider":"SpareOil Automation","version":"1.0","type":"link"}