{"product_id":"atd5s-00-yokogawa-terminal-block-unit-new-original-stock","title":"ATD5S-00 Yokogawa Terminal Block Unit | New \u0026 Original Stock","description":"\u003ch2\u003eYokogawa ATD5S-00 CENTUM Series Terminal Block\u003c\/h2\u003e\n\u003cp\u003eConfigured for field wiring interface execution in CENTUM VP\/CS 3000 systems, the \u003cstrong\u003eYokogawa ATD5S-00\u003c\/strong\u003e (\u003cstrong\u003eATD5S\u003c\/strong\u003e Terminal Block Unit) provides direct physical\/electrical execution. The hardware serves as the physical interface connecting external discrete or analog field components directly to the 32-channel system I\/O modules via a pressure-clamp termination structure.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eATD5S-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e114 x 32.6 x 60.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive device (0 W internal consumption)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Capacity\u003c\/td\u003e\n\u003ctd\u003e32 signal points per block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage\u003c\/td\u003e\n\u003ctd\u003e250 VAC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e5 A maximum continuous per common bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e1500 VAC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003eMinimum 100 MΩ at 500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe Yokogawa ATD5S-00 manages high-density signal distribution without the use of onboard surge absorbers, operating as a direct pass-through terminal matrix. The insulation resistance of 100 MΩ ensures electrical separation between adjacent signal paths, preventing cross-talk and crosstalk-induced signal degradation in paired analog or high-frequency digital loops. Channel-to-channel isolation parameters are dictated by the paired active module, while the physical base unit delivers a dielectric strength of 1500 VAC to protect the internal FIO baseplate components against common-mode voltage spikes arising from external field grounding differentials.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the lack of internal surge absorbers affect installation choices for the -00 suffix variant?\u003c\/p\u003e\n\u003cp\u003eA: The -00 suffix designates a standard terminal assembly without onboard surge suppression components. It must be deployed in environments where external lightning\/surge protection is already established on the signal loops, or for general-purpose digital and analog signal circuits where high-voltage transients are not anticipated.\u003c\/p\u003e\n\u003cp\u003eQ: What are the continuous electrical current limitations when multiple channels are loaded?\u003c\/p\u003e\n\u003cp\u003eA: While individual terminals accommodate standard field signals, the common return bus path features a strict hardware limit of 5 A maximum continuous current. Exceeding this thermal threshold will result in structural degradation of the flame-retardant engineering plastic housing.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure-Clamp Terminal Termination\u003c\/strong\u003e: Strip field conductors to the designated engineering length and use round crimp terminals with M4 screws. Secure the connections within the pressure-clamp terminal blocks using a calibrated torque screwdriver to prevent vibration-induced loosening.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Sizing Requirements\u003c\/strong\u003e: Utilize copper field wiring with a cross-sectional area ranging from 0.5 to 2.5 mm² (equivalent to AWG 20-14). Ensure that the insulation is rated for the maximum expected system loop voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding Matrix\u003c\/strong\u003e: Terminate the external cable shields directly to the dedicated earth\/shield terminal provided on the unit assembly. This path must connect straight to the instrument ground busbar via a low-impedance copper strap to optimize noise immunity.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43509507555418,"sku":"ATB5S-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/379._83356313-728b-499f-871a-39edab03d854.jpg?v=1781665772","url":"https:\/\/www.spareoil.com\/ar\/products\/atd5s-00-yokogawa-terminal-block-unit-new-original-stock","provider":"SpareOil Automation","version":"1.0","type":"link"}