{"product_id":"bently-nevada-330103-00-04-05-02-cn-3300-xl-series-proximity-probe","title":"Bently Nevada 330103-00-04-05-02-CN 3300 XL Series Proximity Probe","description":"\u003cp\u003eConfigured for vibration and displacement monitoring in 3300 XL Transducer System platforms, the \u003cstrong\u003eBently Nevada 330103-00-04-05-02-CN\u003c\/strong\u003e (\u003cstrong\u003e330103\u003c\/strong\u003e Proximity Probe) provides direct physical\/electrical execution. This metric hardware component establishes a high-frequency radio frequency field at the sensor tip, translating physical proximity gaps between the unarmored 8 mm probe face and a rotating conductive metal shaft into proportional electrical modulation loops without physical contact.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330103\u003c\/strong\u003e: Base module parameter for the 3300 XL 8 mm proximity probe utilizing an M10 x 1 thread layout without an interlocking armor sheath.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00\u003c\/strong\u003e: Unthreaded length option, indicating 0.0 mm of smooth, unthreaded barrel depth.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-04\u003c\/strong\u003e: Overall case length option, indicating a 40 mm total threaded housing depth.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-05\u003c\/strong\u003e: Total length option, establishing a 0.5 metre (1.6 feet) integrated cable path length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-02\u003c\/strong\u003e: Connector and cable type option, selecting a miniature coaxial ClickLoc connector matched with a standard electrical cable core.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-CN\u003c\/strong\u003e: Agency approval option, designating country-specific dangerous area markings including regional industrial safety certifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330103-00-04-05-02-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg (2.0 kg shipping weight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e8 mm probe tip diameter, 40 mm case length, M10 x 1 metric thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive hardware element driven by external Proximitor loop excitation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eAISI 303 or 304 Stainless Steel (SST)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene Sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Interface\u003c\/td\u003e\n\u003ctd\u003eClickLoc miniature coaxial assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMechanical Monitoring \u0026amp; TSI Technical Attributes\u003c\/h3\u003e\n\u003cp\u003eThe eddy-current transducer installation requires strict matching to target metallurgy profiles to ensure stable eddy-current probe scaling coefficients across the measurement zone. During field verification, technicians must execute a precise gap voltage validation sequence, mechanically adjusting the probe depth inside the M10 x 1 entry point until the steady-state DC potential registers exactly -10 VDC at the linear center point. This baseline calibration guarantees proper tracking of rapid rotor dynamics and limits physical measurement drift caused by extreme thermal expansion. Cross-talk suppression is maintained by internal coaxial shield density to isolate raw signals from surrounding inductive noise.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What physical handling rule prevents calibration shifts at the ClickLoc connection point?\u003c\/p\u003e\n\u003cp\u003eA: The miniature coaxial ClickLoc connector must be engaged and disengaged by hand pressure only. Using mechanical pliers or wire tools permanently warps the internal gold-plated barrel shell, modifying total loop impedance.\u003c\/p\u003e\n\u003cp\u003eQ: Can this 0.5 metre unarmored cable link directly to a remote 3500 monitor rack terminal block?\u003c\/p\u003e\n\u003cp\u003eA: No. The probe is an inductive element requiring a specific 3300 XL extension cable to build out a complete 5.0 or 9.0 metre balanced network matched to the excitation frequency of the host Proximitor Sensor.\u003c\/p\u003e\n\u003cp\u003eQ: How does liquid or oil exposure on the probe tip affect raw output resolution?\u003c\/p\u003e\n\u003cp\u003eA: The polyphenylene sulfide (PPS) tip material is completely non-conductive. Standard non-conductive machine oil coatings do not impact the eddy-current penetration depth or alter the targeted linear tracking.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eClean out the M10 x 1 metric threaded penetration, ensuring the interface is free of residual drilling metal, old sealants, or carbon scale.\u003c\/li\u003e\n\u003cli\u003eThread the 40 mm stainless steel probe body into the mounting hole by hand to eliminate cross-threading hazards.\u003c\/li\u003e\n\u003cli\u003eHook an external digital multimeter up to the Proximitor loop test points to watch active voltage output during final depth adjustment.\u003c\/li\u003e\n\u003cli\u003eRotate the probe barrel slowly until the gap voltage validation matches the baseline index of -10 VDC.\u003c\/li\u003e\n\u003cli\u003eLock the external hex nut firmly against the machine structural wall to preserve the verified air gap under constant operating vibration, and seal the coaxial junction against moisture using self-fusing insulation tape.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43572472217690,"sku":"330103-00-04-05-02-CN","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/330101-00-08-05-02-00_209cc615-b562-4a3e-ab70-728279398329.png?v=1782791398","url":"https:\/\/www.spareoil.com\/ar\/products\/bently-nevada-330103-00-04-05-02-cn-3300-xl-series-proximity-probe","provider":"SpareOil Automation","version":"1.0","type":"link"}