{"product_id":"bently-nevada-330104-00-09-05-11-05-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330104-00-09-05-11-05 3300 XL 8 mm Proximity Probe","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330104-00-09-05-11-05\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e330104\u003c\/strong\u003e Proximity Probe, operates as a dedicated hardware component for high-precision vibration and position measurement within 3300 XL Machinery Protection System platforms. The probe tip establishes an electromagnetic field to register dynamic shaft displacement, transferring raw gap voltage alterations over a moisture-resistant coaxial transmission line with armor protection back to an external Proximitor Sensor.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOption Category\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Configuration\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e330104\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Probe, M10 x 1 Metric Thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n\u003ctd\u003e0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e09\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOverall Case Length\u003c\/td\u003e\n\u003ctd\u003e90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal Length\u003c\/td\u003e\n\u003ctd\u003e0.5 meter (1.6 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e11\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnector and Cable Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector with connector protector, FluidLoc cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx multiple approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330104-00-09-05-11-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eU.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Type\u003c\/td\u003e\n\u003ctd\u003eM10 x 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n\u003ctd\u003e0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Case Length\u003c\/td\u003e\n\u003ctd\u003e90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Infrastructure\u003c\/td\u003e\n\u003ctd\u003eFluidLoc cable with mechanical armor protection and ClickLoc connector protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive sensor assembly (excited by external Proximitor loop)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e90 mm case length, 0.5 meter total cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eLess than 1.0 kg nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCross-Talk Suppression\u003c\/h3\u003e\n\u003cp\u003eWhen deploying multiple 330104-00-09-05-11-05 probe assemblies inside a single machine bearing housing for orthogonal (X-Y) radial vibration tracking, mechanical spacing must enforce cross-talk suppression. If the physical distance between adjacent 8 mm probe tips falls below 40 mm (1.6 inches), the high-frequency electromagnetic fields will intersect, inducing mutual interference and distorting the voltage-to-displacement calibration. Maintaining strict physical clearance ensures that each module executes independent displacement tracking without cross-channel modulation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can this 0.5-meter probe be directly connected to a standard 5.0-meter Proximitor Sensor?\u003c\/p\u003e\n\u003cp\u003eA: No. Transducer loops require a matched electrical length calibration. A 0.5-meter total length probe must be paired with a 4.5-meter extension cable to complete the necessary 5.0-meter total system length required by the matching Proximitor module.\u003c\/p\u003e\n\u003cp\u003eQ: What specific protection is provided by the combination of a FluidLoc cable and a connector protector?\u003c\/p\u003e\n\u003cp\u003eA: The FluidLoc matrix prevents the internal capillary migration of oil or moisture through the cable jacket if damaged, while the integrated connector protector physically seals the ClickLoc coaxial junction against environmental fluid ingress at the machine boundary.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Torque Limits:\u003c\/strong\u003e When threading the 90 mm metric case into the machine housing, use a calibrated torque wrench to limit mechanical load to a maximum of 33.9 N-m (300 in-lb) to prevent thread binding or casing distortion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmor Bend Radius Restrictions:\u003c\/strong\u003e The protective metal armor jacket shields the internal FluidLoc coaxial line but restricts flexibility. Maintain a minimum structural bend radius of 25.4 mm (1.0 inch) during routing to prevent internal conductor fracturing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Ground Separation:\u003c\/strong\u003e Ensure that the outer metallic structure of the armored cable and the ClickLoc connector protector assembly remains isolated from the machine ground. All signal shields must track back and terminate exclusively at the instrument rack or junction box common ground.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43585423507546,"sku":"330104-00-09-05-11-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/330101-37-57-10-02-051_21bd8714-6582-48cb-a7a9-b9c338b9b3f8.png?v=1783048812","url":"https:\/\/www.spareoil.com\/ar\/products\/bently-nevada-330104-00-09-05-11-05-3300-xl-8-mm-proximity-probe","provider":"SpareOil Automation","version":"1.0","type":"link"}