{"product_id":"bently-nevada-330104-00-13-05-02-00-3300-xl-proximity-probe","title":"Bently Nevada 330104-00-13-05-02-00 3300 XL Proximity Probe","description":"\u003cp\u003eConfigured for non-contacting shaft displacement tracking in 3300 XL Machinery Protection System networks, the \u003cstrong\u003eBently Nevada 330104-00-13-05-02-00\u003c\/strong\u003e (\u003cstrong\u003e330104\u003c\/strong\u003e Proximity Probe) provides direct physical\/electrical execution. The component establishes a localized eddy-current field against rotating or reciprocating machinery shafts, converting physical gap deviations into high-frequency impedance changes that are transmitted via a miniature coaxial cable to an external Proximitor sensor interface.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOption Category\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Configuration\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e330104\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Probe, Metric Thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n\u003ctd\u003e0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e13\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOverall Case Length\u003c\/td\u003e\n\u003ctd\u003e130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal Length\u003c\/td\u003e\n\u003ctd\u003e0.5 meter (1.6 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnector and Cable Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330104-00-13-05-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eU.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Diameter\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Case Material\u003c\/td\u003e\n\u003ctd\u003eAISI 303 or 304 stainless steel (SST)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive sensor (loop-powered via external Proximitor module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e130 mm case length, 0.5 meter total cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.0 kg shipping weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGap Voltage Validation (-10 VDC Targets)\u003c\/h3\u003e\n\u003cp\u003eField calibration requires strict gap voltage validation to anchor the probe within its linear measuring range. During installation, the mechanical depth of the 130 mm stainless steel case must be physically adjusted within the mounting bore while reading the DC bias voltage output from the corresponding Proximitor circuit. Technicians must position the probe tip to secure a static gap voltage validation target of exactly -10 VDC, which positions the target face at the exact center of the linear calibration slope. This precise mechanical positioning ensures linear output for dynamic rotor dynamics monitoring and maximizes cross-talk suppression between close-proximity sensor pairs.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can this 0.5-meter total length probe connect directly to a standard 5.0-meter Proximitor sensor?\u003c\/p\u003e\n\u003cp\u003eA: No. The proximity transducer loop requires a matched total electrical length. A 0.5-meter total length probe must be paired exclusively with a 4.5-meter extension cable to satisfy the total 5.0-meter electrical system length parameter of the Proximitor.\u003c\/p\u003e\n\u003cp\u003eQ: What is the mechanical function of the integrated ClickLoc coaxial connector?\u003c\/p\u003e\n\u003cp\u003eA: The option 02 ClickLoc connector acts as a positive-locking coaxial interface that resists detachment from vibration. It is a dry connection and must be kept clean and free of lubricants or moisture to prevent signal degradation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Torque Restrictions:\u003c\/strong\u003e When installing the 130 mm metric threaded probe housing into the machine housing port, limit mechanical torque to a maximum of 33.9 N-m (300 in-lb) to prevent thread binding or casing structural deformation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoaxial Lead Bend Radius:\u003c\/strong\u003e Route the 0.5-meter standard cable assembly with a minimum bend radius of 25.4 mm (1.0 inch) to protect the internal coaxial shielding layers from mechanical fatigue.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Ground Isolation:\u003c\/strong\u003e Ensure that the outer conductor shell of the ClickLoc connector joint is insulated from the machine casing. All signal shields must terminate at the common terminal ground of the monitoring enclosure to prevent ground loops.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43585434189914,"sku":"330104-00-13-05-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/330101-37-57-10-02-051_0af6d4c5-914b-4bd5-b601-c709e844cd97.png?v=1783049581","url":"https:\/\/www.spareoil.com\/ar\/products\/bently-nevada-330104-00-13-05-02-00-3300-xl-proximity-probe","provider":"SpareOil Automation","version":"1.0","type":"link"}