{"product_id":"bently-nevada-84141-01-xdcr-i-o-record-terminal-1","title":"Bently Nevada 84143-01 XDCR I\/O Record Terminal Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 84143-01 is a dedicated transducer (XDCR) I\/O terminal module engineered for the 3300 Monitoring System. This component serves as the primary interface for field wiring, providing secure, reliable termination points for various industrial sensors, including proximity probes and vibration transducers. By facilitating the transition from field cabling to the internal rack backplane, it ensures the integrity of signal transmission to the monitoring modules responsible for machinery protection and diagnostic analysis.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Interfacing:\u003c\/strong\u003e Offers a robust termination interface for proximity probes and vibration sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e Designed specifically for the 3300 series rack architecture to ensure seamless signal routing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliability:\u003c\/strong\u003e Engineered to maintain signal quality in critical rotating machinery environments such as compressors and turbines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eForm Factor:\u003c\/strong\u003e Utilizes a standard 3300 series half-height rack profile for space-efficient installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePassive Design:\u003c\/strong\u003e Operates as a passive termination unit, requiring no external power supply.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis terminal module is essential for predictive maintenance and machinery protection systems. It is commonly deployed in power generation, petrochemical processing, and heavy manufacturing facilities to support the monitoring of:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSteam and gas turbines\u003c\/li\u003e\n\u003cli\u003eCentrifugal and reciprocating compressors\u003c\/li\u003e\n\u003cli\u003eLarge industrial pumps and motors\u003c\/li\u003e\n\u003cli\u003eGearboxes and fans\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e84143-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eXDCR I\/O Record Terminal Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 degC to +60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive (Negligible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Compatibility\u003c\/td\u003e\n\u003ctd\u003eProximity probes, vibration transducers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Precautions:\u003c\/strong\u003e Always follow electrostatic discharge (ESD) prevention protocols when handling the module to protect internal circuitry.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Seating:\u003c\/strong\u003e Ensure the module is fully seated and aligned within the 3300 rack slots before securing the front panel screws.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Integrity:\u003c\/strong\u003e Verify that all sensor field wires are properly stripped and secured to the terminal blocks to prevent intermittent signal loss.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Ensure the cabinet environment is maintained within the specified 0 degC to +60 degC range and is free from excessive vibration or corrosive gases.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Status:\u003c\/strong\u003e Although this is a passive module, it is recommended to ensure the rack system is properly grounded before performing any maintenance or wiring adjustments.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eIs the 84143-01 an active or passive module?\u003c\/strong\u003e\u003cbr\u003eThe 84143-01 is a passive terminal module. It does not require power to function; its primary purpose is to provide a reliable electrical connection and signal routing for transducer inputs.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan this module be used outside of the 3300 system?\u003c\/strong\u003e\u003cbr\u003eNo, this module is specifically designed for the mechanical and electrical architecture of the Bently Nevada 3300 Monitoring System.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44019592527962,"sku":"84143-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_8095517a-cd60-49e9-885f-449cf566c5e2.jpg?v=1788658739","url":"https:\/\/www.spareoil.com\/ar\/products\/bently-nevada-84141-01-xdcr-i-o-record-terminal-1","provider":"SpareOil Automation","version":"1.0","type":"link"}