{"product_id":"d0162lq-foxboro-operator-interface-panel-datasheet","title":"D0162LQ Foxboro Operator Interface Panel Datasheet","description":"\u003ch2\u003eFoxboro D0162LQ Operator Interface Panel\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFoxboro D0162LQ\/H\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eD0162LQ\u003c\/strong\u003e Indicator Module, operates as a dedicated hardware component for localized data visualization and diagnostic execution within Mesh Control Network platforms. The component establishes direct physical interface links with the FCM100E module, operating at a data throughput speed of 100 Mbps across the control infrastructure.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eD0162LQ\/H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFoxboro (Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.37 lbs (1 kg shipping weight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard FCM100E slot footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSourced via system backplane connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eLCD Indicator Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Velocity\u003c\/td\u003e\n\u003ctd\u003e100 Mbps Mesh Control Network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Resistance\u003c\/td\u003e\n\u003ctd\u003eClass G3 - ISA S71.04 harsh environment rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination Type\u003c\/td\u003e\n\u003ctd\u003eScrew-clamp terminals (12-22 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP20 (cabinet installation required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; DCS Instrumentation Properties\u003c\/h3\u003e\n\u003cp\u003eThe hardware acts as a physical node interface processing diagnostic data streams directly from the network layer. Channel-to-channel isolation circuits safeguard the internal processing bus from external electrical noise and ground voltage variations. The operator interface structure interfaces directly with the 100 Mbps Mesh Control Network, utilizing standard protocols to mirror process parameters from paired fieldbus modules and display loop dynamics without introducing channel latency or data degradation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What specific environmental rating governs the protection of the internal circuitry?\u003c\/p\u003e\n\u003cp\u003eA: The hardware is certified to Class G3 specifications according to ISA S71.04, rendering it resistant to continuous chemical and corrosive particulate exposures commonly found in unregulated control environments.\u003c\/p\u003e\n\u003cp\u003eQ: Does the indicator panel require independent external power routing?\u003c\/p\u003e\n\u003cp\u003eA: No external power connections are necessary. The assembly derives its operational voltage directly from the system rack backplane when seated in its designated slot pairing.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Insertion:\u003c\/strong\u003e Guide the module along the chassis rails into the FCM100E assembly socket. Apply uniform pressure until the locking tabs snap into place, establishing firm connection with the 100 Mbps data plane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding Constraints:\u003c\/strong\u003e Ground all external network and signal shielding lines at a single common master ground point within the instrument enclosure. Do not create loops by grounding both ends of the cable run.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e Mount the unit vertically within an IP20 enclosure, keeping a minimum clearance of 50 mm above and below the housing to maintain temperature values within the -20 to +60 deg C operational envelope.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":43454298849370,"sku":"D0162LQ\/H","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/395._76f1b2fe-adbc-4dfa-90d0-c28a6a975edf.jpg?v=1780622631","url":"https:\/\/www.spareoil.com\/ar\/products\/d0162lq-foxboro-operator-interface-panel-datasheet","provider":"SpareOil Automation","version":"1.0","type":"link"}