{"product_id":"digital-input-module-yokogawa-adv151-p03-centum-vp-fio","title":"Digital Input Module | Yokogawa ADV151-P03 CENTUM VP FIO","description":"\u003ch2\u003eYokogawa ADV151-P03 Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa ADV151-P03\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eADV151\u003c\/strong\u003e Digital Input Module, operates as a dedicated hardware component for ON\/OFF signal acquisition within CENTUM VP Distributed Control System (DCS) platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV151-P03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e32-channel input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (sink\/source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput ON Voltage\u003c\/td\u003e\n\u003ctd\u003e18 to 26.4 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput OFF Voltage\u003c\/td\u003e\n\u003ctd\u003eLess than or equal to 5.0 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e4.1 mA (plus or minus 20 percent per channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Allowable Voltage\u003c\/td\u003e\n\u003ctd\u003e30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e2 kV AC (input-to-system, 1 min); 500 V AC (between commons, 1 min, every 16 channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e500 mA (5 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eLess than or equal to 8 ms (status input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eSupports dual redundant configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, ISA G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Process Control \u0026amp; Instrumentation Attributes\u003c\/h3\u003e\n\u003cp\u003eThe ADV151-P03 incorporates channel-to-channel isolation architecture segmented into two discrete groups of 16 channels each. This isolation topology prevents transient electrical surges from propagating across the internal system backplane. Designed specifically for the FIO architecture of the CENTUM VP system, the module coordinates direct edge-counting execution and status input detection at a hardware level, eliminating reliance on software polling loops. It integrates hardware-level digital filtering to suppress high-frequency line noise and mechanical switch bounce, ensuring deterministic signal state transitions back to the main control processors.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module support online hot-swap operations within a redundant architecture?\u003c\/p\u003e\n\u003cp\u003eA: Yes. When deployed in a dual redundant configuration on an active FIO node, a faulty module can be extracted and replaced without interrupting power to the backplane or terminating the signal acquisition of the partner module.\u003c\/p\u003e\n\u003cp\u003eQ: What are the specific power distribution constraints across the input channels?\u003c\/p\u003e\n\u003cp\u003eA: The module accommodates both sink and source wiring topologies, but all 24 V DC signals routed to the module must share the identical electrical polarity across all 32 channels to prevent damage to the internal logic circuitry.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Method:\u003c\/strong\u003e Secure the module firmly onto the specified FIO base plate slot. Verify that the dual locking mechanisms click completely into place to prevent intermittent backplane connections caused by industrial vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Interface:\u003c\/strong\u003e Use dedicated pressure clamp terminals, MIL connector cables, or Yokogawa AKB331 cables. Note that the system-level isolation values are dependent on the specific cable shielding and interface connectors used.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e Terminate cable shields at the designated cabinet instrument ground bar. Maintain physical separation between the 24 V DC signal lines and heavy AC power distribution cabling inside the enclosure to eliminate electromagnetic cross-talk.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43664927293530,"sku":"ADV151-P03","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/362_7341b8cb-dbf2-4c4a-b840-402ac74156ee.jpg?v=1784170461","url":"https:\/\/www.spareoil.com\/ar\/products\/digital-input-module-yokogawa-adv151-p03-centum-vp-fio","provider":"SpareOil Automation","version":"1.0","type":"link"}