{"product_id":"digital-input-module-yokogawa-adv151-p13-d5a00-centum-vp","title":"Digital Input Module | Yokogawa ADV151-P13\/D5A00 CENTUM VP","description":"\u003ch2\u003eYokogawa ADV151-P13\/D5A00 Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa ADV151-P13\/D5A00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eADV151\u003c\/strong\u003e Digital Input Module, operates as a dedicated hardware component for discrete field signal acquisition and contact status processing within CENTUM VP and CS 3000 DCS platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCode Component\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCode Option\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Definition\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV151\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module (32-channel, 24 VDC, Isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuffix - Type\u003c\/td\u003e\n\u003ctd\u003e-P\u003c\/td\u003e\n\u003ctd\u003eStandard type with basic execution features\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuffix - Features\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eStandard specification without status display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuffix - Protection\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eWith ISA Standard G3 option and extended temperature (-20 to 70 deg C) option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption Code\u003c\/td\u003e\n\u003ctd\u003e\/D5A00\u003c\/td\u003e\n\u003ctd\u003eWith KS Cable Interface Adapter for 32-channel digital signals (ATD5A-00)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV151-P13\/D5A00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.6 kg Net \/ 1.5 kg Shipping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCompact modular design for CENTUM VP nest\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e200 mA at 5 VDC, 30 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e32 Digital Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Thresholds\u003c\/td\u003e\n\u003ctd\u003eON state \u0026gt;= 15 VDC, OFF state \u0026lt;= 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e4 to 7 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 VAC withstand between field and system logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 5 ms ON\/OFF switch latency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eCE, UL, RoHS, ISA Standard G3 protective coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Interface Features\u003c\/h3\u003e\n\u003cp\u003eThe unit integrates 32 isolated digital input channels to acquire field contacts while maintaining galvanic isolation up to 1500 VAC. The module routes status signals across the DCS backplane bus directly to Field Control Stations. The onboard KS cable interface adapter (\/D5A00) allows direct connection to external terminal panels, preserving channel-to-channel isolation and shielding internal logic against transient field surges.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the direct manufacturer-designated functional replacement for the ADV151-P13\/D5A00 module?\u003c\/p\u003e\n\u003cp\u003eA: Yokogawa designates the ADV151-P63\/D5A00 module as the direct functional replacement. The replacement unit retains identical 32-channel 24 VDC electrical parameters while adding front-panel LED status displays.\u003c\/p\u003e\n\u003cp\u003eQ: Can engineers hot-swap the ADV151-P13\/D5A00 module during system operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes. You can remove and replace the module online without interrupting active Field Control Station execution or de-energizing adjacent system cards on the I\/O node nest.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Insertion and Grounding:\u003c\/strong\u003e Slide the module firmly into its designated slot in the CENTUM I\/O nest until the top and bottom latches lock cleanly. Verify that the node chassis earth braid connects directly to the panel protective conductor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKS Cable Adapter Routing:\u003c\/strong\u003e Fasten the KS cable interface adapter (\/D5A00) securely to the module front connector. Route signal multi-cores through cable troughs to prevent mechanical strain on the module interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding Termination Rules:\u003c\/strong\u003e Terminate incoming field cable shields at the dedicated earth bar on the termination assembly. Keep shield drain wires isolated from field common lines to uphold the 1500 VAC isolation barrier.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43859787874394,"sku":"ADV151-P13\/D5A00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/568_ffb7f3b0-9c7a-44c7-bd14-b9aef5e1e140.jpg?v=1787024357","url":"https:\/\/www.spareoil.com\/ar\/products\/digital-input-module-yokogawa-adv151-p13-d5a00-centum-vp","provider":"SpareOil Automation","version":"1.0","type":"link"}