{"product_id":"digital-input-module-yokogawa-sdv144-s53-fio-series","title":"Digital Input Module | YOKOGAWA SDV144-S53 FIO Series","description":"\u003ch2\u003eYOKOGAWA SDV144-S53 FIO Series Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for discrete signal acquisition in CENTUM VP\/CS distributed control systems, the \u003cstrong\u003eYOKOGAWA SDV144-S53\u003c\/strong\u003e (\u003cstrong\u003eSDV144\u003c\/strong\u003e Digital Input Module) provides direct physical\/electrical execution. This high-density module captures binary ON\/OFF states from field hardware including limit switches, pushbuttons, and safety interlocks, transforming physical contact closures into digital data packages for processing across the control network. The physical design features specialized electrical isolation barriers to prevent field-side voltage transients from damaging the internal logic circuitry.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model (SDV144)\u003c\/strong\u003e: 64-channel digital input module design utilizing FIO architecture for system integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eS Suffix\u003c\/strong\u003e: Identifies the standard performance configuration tier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5 Suffix\u003c\/strong\u003e: Designates electrical termination compatibility for pressure clamp terminal blocks or MIL connector cable installations without specialized explosion protection requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3 Suffix\u003c\/strong\u003e: Denotes factory compliance with ISA Standard G3 conformal coating regulations and supports an extended operating environment envelope.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSDV144-S53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg (Shipping Weight: 2 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e130 x 119.9 x 32.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e~550 mA at 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (Operational range: 20.4-26.4 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput ON Voltage\u003c\/td\u003e\n\u003ctd\u003e20-26.4 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput OFF Voltage\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 5.0 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e~2.5 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Allowable Voltage\u003c\/td\u003e\n\u003ctd\u003e30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 3 ms typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Capacity\u003c\/td\u003e\n\u003ctd\u003e64 digital inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e2 kV AC (signal-to-system, 1 min); 500 V AC between commons per 16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connection\u003c\/td\u003e\n\u003ctd\u003eMIL connector cable (AKB337)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3 conformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; DCS Instrumentation Technical Attributes\u003c\/h3\u003e\n\u003cp\u003eThe module implements high-density optocoupler arrays to enforce rigid channel-to-channel isolation between distinct 16-channel common groups, rated at 500 V AC. Engineers achieve total physical isolation between field wiring terminals and the central processing backplane via a 2 kV AC galvanic barrier. Signal processing hardware evaluates incoming logic states within a \u0026lt;= 3 ms hardware response time, providing edge counting capabilities alongside standard status detection. To maintain execution fidelity under volatile thermodynamic conditions, the component operates across a comprehensive -20 to +70 deg C range, relying on an internal thermal dissipation layout that prevents internal heat accumulation without the use of active cooling fans. The factory-applied ISA Standard G3 conformal coating shields exposed copper traces from continuous chemical exposure, preventing dendritic growth caused by moisture or industrial atmospheric contaminants.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the A-D conversion or filtering loop support field-adjustable debounce filters?\u003c\/p\u003e\n\u003cp\u003eA: The hardware logic layer enforces a fixed response filter designed to capture discrete transitions down to 3 ms. Users who require additional contact de-bouncing must program supplementary timers directly within the DCS application software, as the module passes the raw hardware state directly to the backplane to minimize latency.\u003c\/p\u003e\n\u003cp\u003eQ: What are the installation restrictions concerning the MIL interface connection?\u003c\/p\u003e\n\u003cp\u003eA: Technicians must utilize the dedicated AKB337 MIL connector cable assembly. The module relies on rigid structural alignment pins to distribute external strain away from the internal pins; ensuring proper seating prevents field-side cross-talk and minimizes contact resistance variances across high-density loop groupings.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Node Mounting\u003c\/strong\u003e: Align the module vertically with the target slot on the FIO base plate assembly. Push the module forward until the rear backplane connectors seat fully, then lock the retention levers to guarantee mechanical and electrical stability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMIL Cable Termination\u003c\/strong\u003e: Insert the AKB337 MIL connector assembly into the front panel interface. Tighten the physical cable strain-relief mechanisms to eliminate physical pulling forces on individual electrical conductor terminations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield and Common Grounding\u003c\/strong\u003e: Route the signal commons through the independent isolated banks. Terminate all instrument shields directly to a single-point instrumentation ground bus bar, ensuring you do not introduce multi-point loops that compromise the 2 kV AC signal-to-system galvanic boundary.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Monitoring\u003c\/strong\u003e: Ensure the field enclosure maintains free vertical air convection. Leave appropriate clearance spaces around the module chassis to ensure ambient conditions do not exceed the stated 70 deg C hardware performance rating.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43778121695322,"sku":"SDV144-S53","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/706..jpg?v=1785724956","url":"https:\/\/www.spareoil.com\/ar\/products\/digital-input-module-yokogawa-sdv144-s53-fio-series","provider":"SpareOil Automation","version":"1.0","type":"link"}