{"product_id":"digital-output-module-yokogawa-adv551-p10-s2-centum-vp","title":"Digital Output Module | Yokogawa ADV551-P10 S2 CENTUM VP","description":"\u003ch2\u003eYokogawa ADV551-P10 S2 Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-speed signal actuation in Yokogawa DCS platforms, the \u003cstrong\u003eYokogawa ADV551-P10 S2\u003c\/strong\u003e (\u003cstrong\u003eADV551\u003c\/strong\u003e Digital Output Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV551-P10 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan \/ Indonesia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e130 mm x 100 mm x 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e700 mA (5 VDC internal), 60 mA (24 VDC external)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e16 isolated digital outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e1 ms typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel and channel-to-system isolation (2000 VAC withstand)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; HART Loop Management\u003c\/h3\u003e\n\u003cp\u003eThe module incorporates robust channel-to-channel galvanic isolation designed to eliminate ground loops and suppress transient electrical noise across field-side connections. Engineered for high-density DCS integration, each output circuit limits cross-channel interference during inductive load switching, ensuring signal integrity across all 16 channels. The hardware architecture prevents field fault propagation to the internal system backplane, enabling simultaneous execution of fast-response discrete switching and stable co-located 4-20 mA HART loop protocol signaling within the same control enclosure.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module support online replacement while the DCS backplane is powered?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports hot-swap functionality. Users can extract or insert the unit online without interrupting system backplane communication or disturbing adjacent I\/O modules, provided standard field terminal removal procedures are followed.\u003c\/p\u003e\n\u003cp\u003eQ: How does the unit react when an individual channel encounters an external short-circuit?\u003c\/p\u003e\n\u003cp\u003eA: Each individual output channel features dedicated short-circuit and overload protection circuits. Upon detecting an overcurrent condition, the affected channel isolates its field drive to prevent hardware damage, while adjacent channels continue normal execution without system failure.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the unit directly into the dedicated CENTUM VP I\/O rack or standard DIN-rail interface using the integrated locking mechanism. Ensure all field wiring maintains proper shield grounding at a single designated point to eliminate potential ground potential differences. Route 24 VDC external load cables separately from sensitive analog input wiring to minimize electromagnetic interference. Verify that terminal screw engagement meets standard industrial torque specs before applying power to the field-side supply circuit.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43859605192794,"sku":"ADV551-P10 S2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/45_f6aee0ab-2da7-4cdd-91cb-1b03940760b8.jpg?v=1787019390","url":"https:\/\/www.spareoil.com\/ar\/products\/digital-output-module-yokogawa-adv551-p10-s2-centum-vp","provider":"SpareOil Automation","version":"1.0","type":"link"}