{"product_id":"emerson-deltav-kj3002x1-bg2-12p1731x082","title":"Emerson DeltaV KJ3002X1-BG2 12P1731X082 8-Channel Thermocouple\/mV Input Module","description":"\u003cp\u003eThe Emerson DeltaV KJ3002X1-BG2 (12P1731X082) is an 8-channel analog input module designed for precision signal acquisition within the DeltaV Scalable Process System. This module is specifically optimized for processing thermocouple and millivolt (mV) inputs, providing reliable data conversion for critical temperature and low-voltage monitoring applications in demanding industrial environments.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e8-channel input capacity for high-density signal monitoring.\u003c\/li\u003e\n\u003cli\u003eDirect compatibility with various thermocouple types and millivolt sensors.\u003c\/li\u003e\n\u003cli\u003eSupports Removal and Insertion Under Power (RIUP) in designated Zone 2 environments.\u003c\/li\u003e\n\u003cli\u003eDesigned for G3 harsh environment compliance per ISA-S71.04-1985.\u003c\/li\u003e\n\u003cli\u003eIntegrated mechanical keying (Position B2) to prevent incorrect module-to-terminal block mating.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is widely utilized in process control sectors, including petrochemical refining, power generation, and heavy manufacturing, where accurate thermal sensing is essential for maintaining process stability and safety.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKJ3002X1-BG2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e12P1731X082\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Types\u003c\/td\u003e\n\u003ctd\u003eThermocouple, Millivolt (mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocalBus Power\u003c\/td\u003e\n\u003ctd\u003e12 VDC @ 350 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Circuit Rating\u003c\/td\u003e\n\u003ctd\u003e5.5 VDC @ 0.6 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% Non-Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e10g (1\/2 Sinewave, 11 msec)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e1mm P-P (5-16Hz); 0.5g (16-150Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04-1985 Class G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the terminal block is correctly keyed to position B2 before installation.\u003c\/li\u003e\n\u003cli\u003eRIUP functionality requires adherence to power conditions; verify primary circuit inductance is below 23 uH.\u003c\/li\u003e\n\u003cli\u003eAlways disconnect field power at the terminal level before removing the module to ensure circuit integrity.\u003c\/li\u003e\n\u003cli\u003eMaintain proper ventilation in the cabinet to stay within the 0-60 deg C ambient temperature range.\u003c\/li\u003e\n\u003cli\u003eHandle with standard ESD precautions to prevent damage to sensitive electronic components.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eIs this module field-calibrated?\u003c\/h3\u003e\u003cp\u003eNo, the KJ3002X1-BG2 is factory-calibrated and contains no user-serviceable parts. Field calibration is not required or supported.\u003c\/p\u003e\u003ch3\u003eWhat is the required keying for this module?\u003c\/h3\u003e\u003cp\u003eThe module must be used with a terminal block keyed to position B2 to ensure correct hardware alignment and safety.\u003c\/p\u003e\u003ch3\u003eCan this module be used in hazardous areas?\u003c\/h3\u003e\u003cp\u003eYes, it is certified for use in Zone 2 hazardous atmospheres under the designation II 3 G, EEx nL IIC T4, provided it is installed according to local safety regulations.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":44024847859802,"sku":"KJ3002X1-BG2 12P1731X082","price":89.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_da262172-f0f3-40fe-b811-c2dcf30796f3.jpg?v=1788776806","url":"https:\/\/www.spareoil.com\/ar\/products\/emerson-deltav-kj3002x1-bg2-12p1731x082","provider":"SpareOil Automation","version":"1.0","type":"link"}