{"product_id":"emerson-deltav-se4601t07-kl4201x1-ba1-charm-baseplate","title":"Emerson DeltaV KL4201X1-BA1 SE4601T07 12-Slot CHARM Baseplate","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Emerson DeltaV KL4201X1-BA1 (assembly code SE4601T07) is a core infrastructure component of the DeltaV Electronic Marshalling architecture. This 12-slot CHARM Baseplate serves as the physical and electrical mounting platform for Characterization Modules (CHARMs). By facilitating individual channel-to-channel isolation and flexible I\/O mapping, it eliminates the requirement for traditional cross-marshalling cabinets. This design supports late-stage I\/O definition and hot-swappable module replacement, which reduces commissioning time and enhances system availability in critical industrial control environments.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupports up to 12 individual CHARM modules in a single high-density footprint.\u003c\/li\u003e\n\u003cli\u003eRedundant power and communication buses ensure high reliability and fault tolerance.\u003c\/li\u003e\n\u003cli\u003eElectrically independent slots prevent fault propagation between connected field devices.\u003c\/li\u003e\n\u003cli\u003eRobust mechanical design featuring an integrated grounding bar for secure DIN-rail mounting.\u003c\/li\u003e\n\u003cli\u003eCompatible with both S-series and M-series DeltaV hardware architectures.\u003c\/li\u003e\n\u003cli\u003eSupports a wide range of signal types, including Analog Input, Digital Input, and Temperature sensing.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis baseplate is engineered for high-density automation environments, including oil and gas refineries, pharmaceutical manufacturing, and offshore platforms. It is ideal for safety-critical and general-purpose control loops where space optimization and reduced wiring complexity are required.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKL4201X1-BA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssembly Code\u003c\/td\u003e\n\u003ctd\u003eSE4601T07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity\u003c\/td\u003e\n\u003ctd\u003e12-Slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 percent (Non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Current\u003c\/td\u003e\n\u003ctd\u003e3.0 Amps per baseplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Area Rating\u003c\/td\u003e\n\u003ctd\u003eATEX II 3 G, Ex nA IIC T4 Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e1 mm peak-to-peak (2-13.2 Hz); 0.7 g (13.2-150 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirborne Contaminants\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04-1985 Class G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the DIN-rail is securely mounted and properly grounded before installing the baseplate.\u003c\/li\u003e\n\u003cli\u003ePower down the system before inserting or removing any CHARM modules to prevent electrical arcing or damage to the backplane.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate ventilation clearance around the baseplate to operate within the specified -40 to 70 deg C temperature range.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for field signals to minimize EMI\/RFI interference in high-noise industrial environments.\u003c\/li\u003e\n\u003cli\u003eHandle with care to avoid electrostatic discharge (ESD) damage to the communication pins.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eIs this baseplate compatible with all CHARM types?\u003c\/h3\u003e\u003cp\u003eYes, the KL4201X1-BA1 is designed as a universal carrier for DeltaV CHARMs, supporting Analog, Digital, and Temperature sensing modules.\u003c\/p\u003e\u003ch3\u003eCan I replace a CHARM module while the system is running?\u003c\/h3\u003e\u003cp\u003eYes, the DeltaV Electronic Marshalling system supports hot-swapping of CHARM modules, allowing for maintenance without requiring a system shutdown.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43800859181146,"sku":"SE4601T07  KL4201X1-BA1","price":89.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_62b1b3f2-723e-45d7-ad3c-deb6bc76abdd.jpg?v=1786154443","url":"https:\/\/www.spareoil.com\/ar\/products\/emerson-deltav-se4601t07-kl4201x1-ba1-charm-baseplate","provider":"SpareOil Automation","version":"1.0","type":"link"}