{"product_id":"emerson-deltav-ve4002s1t1b2-kj3001x1-bg1-12p0557x162","title":"Emerson DeltaV VE4002S1T1B2 KJ3001X1-BG1 12P0557X162 Digital Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Emerson DeltaV VE4002S1T1B2, also identified by part number 12P0557X162 and order code KJ3001X1-BG1, is a specialized digital output isolated terminal block. Engineered for the DeltaV distributed control system architecture, this module acts as a secure interface between control logic and field-mounted actuators. It provides eight channels of isolated discrete signaling, specifically designed to maintain signal integrity and electrical protection in high-stakes industrial environments such as chemical processing, oil and gas, and utility power generation.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolated Channel Architecture:\u003c\/strong\u003e Offers galvanic separation between field-side loads and the internal controller backplane, effectively mitigating ground loops and reducing the risk of EMI-related interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Monitoring:\u003c\/strong\u003e Equipped with integrated LED indicators for each of the eight output channels, allowing for immediate visual status verification and simplified field maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e Designed for integration into DeltaV S-series and M-series hardware environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swappable Design:\u003c\/strong\u003e Supports removal and replacement while the system is energized, minimizing process downtime during routine maintenance or module replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is intended for use in demanding process control applications where electrical isolation is required to protect sensitive controller hardware from field-side transients. It is commonly deployed to drive discrete actuators, relays, and solenoid valves within the DeltaV ecosystem.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eVE4002S1T1B2 \/ KJ3001X1-BG1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e12P0557X162\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Isolated Terminal Block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e250 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 percent (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Status:\u003c\/strong\u003e While the module supports hot-swapping, ensure the specific slot is configured for such operations within the DeltaV system software before removal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Precautions:\u003c\/strong\u003e Always utilize an anti-static wrist strap or appropriate ESD-safe workstation practices when handling the module to prevent damage to internal circuitry.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Integrity:\u003c\/strong\u003e Ensure all field wiring is properly secured to the terminal block. Verify that cable shielding is correctly grounded to prevent noise coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Install in a clean, dry environment within the specified temperature range to ensure optimal longevity and performance.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eIs the VE4002S1T1B2 compatible with older M-series controllers?\u003c\/strong\u003e Yes, this module is designed for compatibility within the broader DeltaV controller ecosystem, including M-series and S-series hardware.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the isolation on this module?\u003c\/strong\u003e The isolation prevents electrical transients from the field side from reaching the system backplane, protecting the main controller from potential damage due to short circuits or high-voltage spikes.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":44003542827098,"sku":"VE4002S1T1B2 KJ3001X1-BG1 12P0557X162","price":89.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_3f9385f6-8b87-4ed6-ba28-b98a79d606f3.jpg?v=1788374726","url":"https:\/\/www.spareoil.com\/ar\/products\/emerson-deltav-ve4002s1t1b2-kj3001x1-bg1-12p0557x162","provider":"SpareOil Automation","version":"1.0","type":"link"}