{"product_id":"emerson-kj4001x1-ba2-ve3051co-12p1562x012-deltav-power-carrier-module","title":"Emerson KJ4001X1-BA2 VE3051CO 12P1562X012 DeltaV Power Carrier Module","description":"\u003cp\u003eThe Emerson KJ4001X1-BA2 (also identified as VE3051CO or 12P1562X012) is a 2-wide power controller carrier engineered for the DeltaV M-Series distributed control system. This module serves as a fundamental physical and electrical interface, providing secure mounting and stable power distribution for controllers and power supply units across the LocalBus. Designed for demanding industrial environments, it ensures the reliability of the control network in sectors such as power generation, chemical processing, and large-scale manufacturing.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDesigned specifically for the DeltaV M-Series architecture.\u003c\/li\u003e\n\u003cli\u003e2-wide carrier configuration for efficient cabinet space utilization.\u003c\/li\u003e\n\u003cli\u003eFacilitates reliable power distribution and LocalBus communication.\u003c\/li\u003e\n\u003cli\u003eRated for operation in hazardous area environments (II 3 G).\u003c\/li\u003e\n\u003cli\u003eSupports robust mechanical mounting for high-vibration industrial settings.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis carrier is intended for use in DeltaV control cabinets where high-availability power management is required. It is suitable for applications involving continuous process control, safety-critical instrumentation, and complex automation systems where system uptime and signal integrity are paramount.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKJ4001X1-BA2 (12P1562X012)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eDeltaV M-Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Rating\u003c\/td\u003e\n\u003ctd\u003e30 VDC, 8 A Max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 percent (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Rating\u003c\/td\u003e\n\u003ctd\u003eII 3 G \/ EEx nA IIC T4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eNemko 02ATEX431U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContaminant Rating\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04-1985 Class G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e1 mm P-P (5-16 Hz); 0.5g (16-150 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Bus Length\u003c\/td\u003e\n\u003ctd\u003e6.5 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system is fully de-energized before installing or removing the carrier or any associated LocalBus cables.\u003c\/li\u003e\n\u003cli\u003eUse KJ4001X1-FA1 module covers on all unused slots to prevent dust and debris ingress.\u003c\/li\u003e\n\u003cli\u003eVerify that the total length of the LocalBus, including all I\/O carriers and extenders, does not exceed 6.5 meters to maintain signal timing.\u003c\/li\u003e\n\u003cli\u003eMount in a clean, ventilated enclosure to maintain the specified IP20 protection and operating temperature range.\u003c\/li\u003e\n\u003cli\u003eHandle with standard ESD precautions to prevent damage to sensitive electronic components.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the KJ4001X1-BA2?\u003c\/strong\u003e\u003cbr\u003eThis module acts as a base carrier for DeltaV controllers, providing the necessary mechanical support and electrical power interface to the LocalBus.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan this module be used in hazardous locations?\u003c\/strong\u003e\u003cbr\u003eYes, it is rated for use in hazardous areas under II 3 G \/ EEx nA IIC T4 standards, provided it is installed according to the relevant ATEX guidelines.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs there a limit to the bus length when using this carrier?\u003c\/strong\u003e\u003cbr\u003eYes, the total combined length of all I\/O carriers and LocalBus extenders in a single chain must not exceed 6.5 meters.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43981194068058,"sku":"KJ4001X1-BA2 VE3051CO 12P1562X012","price":89.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_f1e7fb57-fd04-4f1d-81e8-1a96f1b5448f.jpg?v=1788225104","url":"https:\/\/www.spareoil.com\/ar\/products\/emerson-kj4001x1-ba2-ve3051co-12p1562x012-deltav-power-carrier-module","provider":"SpareOil Automation","version":"1.0","type":"link"}