{"product_id":"f-3330-hima-984333002-hiquad-safety-plc-digital-output-module-24vdc","title":"F 3330 HIMA 984333002 HIQuad Safety PLC Digital Output Module 24VDC","description":"\u003ch2\u003eHIMA F3330 Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHIMA F3330\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eF3330\u003c\/strong\u003e Digital Output Module (Part No: 984333002), operates as a dedicated hardware component for driving discrete safety actuation loops and field load switches within HIQuad safety PLC system platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF3330 (Part No: 984333002)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHIMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.25 kg (module) \/ 0.60 kg (system weight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e207 x 147 x 67 mm (4 TE rack width)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e110 mA at 5 VDC + 180 mA at 24 VDC (excluding load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Channel Density\u003c\/td\u003e\n\u003ctd\u003e8 independent safety digital output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003eMax 500 mA per channel (short-circuit proof)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Limits\u003c\/td\u003e\n\u003ctd\u003eResistive\/inductive up to 12 W; lamp loads up to 4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Voltage Drop\u003c\/td\u003e\n\u003ctd\u003eMax 2 V at full load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current\u003c\/td\u003e\n\u003ctd\u003eMax 350 uA when deactivated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eMax 8 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Resistance Limit\u003c\/td\u003e\n\u003ctd\u003eMax 11 ohm combined input\/output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Integrity Level\u003c\/td\u003e\n\u003ctd\u003eIEC 61508 SIL3, EN ISO 13849-1 PL e, TÜV certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eSelf-test, walking-bit test, short-circuit detection, undervoltage tripping at max 16 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eRack-mounted (HIQuad subrack)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGalvanic Isolation \u0026amp; Fail-Safe State Execution\u003c\/h3\u003e\n\u003cp\u003eThe HIMA F3330 module relies on internal galvanic isolation barriers to decouple field-side 24 VDC switching circuits from the internal processing logic and system backplane bus. This electrical separation prevents external ground loops and voltage surges from propagating into central processor modules.\u003c\/p\u003e\n\u003cp\u003eIntegrated diagnostic routines continuously perform walking-bit tests, current monitoring, and line surveillance on each of the 8 channels. Certified to IEC 61508 SIL3 standards, any detected short-circuit event, cross-talk fault, or supply drop below 16 VDC forces the module into immediate fail-safe state execution, driving the affected output loop into a safe, de-energized condition without compromising system integrity.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the F3330 module react when the field power supply drops below normal operating thresholds?\u003c\/p\u003e\n\u003cp\u003eA: The module incorporates automatic undervoltage tripping logic that forces the digital output channels into a safe, de-energized state if the input supply voltage drops to 16 VDC or below.\u003c\/p\u003e\n\u003cp\u003eQ: What are the primary channel loading limits for resistive and lamp loads?\u003c\/p\u003e\n\u003cp\u003eA: Each individual output channel supports continuous loads up to 500 mA, accommodating resistive and inductive loads up to 12 W or incandescent lamp loads up to 4 W.\u003c\/p\u003e\n\u003cp\u003eQ: Can the F3330 module be hot-swapped during active controller operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes, provided the HIQuad chassis configuration and system safety guidelines permit hot-swapping under powered conditions without interrupting adjacent subrack I\/O signals.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInsert the F3330 module into its designated slot within the HIQuad 4 TE subrack chassis, ensuring backplane connectors engage fully before tightening top and bottom panel retaining screws. Maintain a minimum vertical clearance of 50 mm above and below the subrack to ensure passive convection airflow across the -20 to +60 deg C operating temperature spectrum.\u003c\/p\u003e\n\u003cp\u003eRoute 24 VDC field output wiring through grounded metal conduits or dedicated wiring ducts, keeping signal runs separated from high-voltage AC lines. Ensure field loop line resistance does not exceed 11 ohm total, terminate cable shielding directly at the cabinet earthing bar, and verify output load current demands do not exceed 500 mA per channel prior to energizing the module.\u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":43782701187162,"sku":"F3330","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/310._3dca5523-e05e-40c6-9112-bcc2c0df2a0d.jpg?v=1785813085","url":"https:\/\/www.spareoil.com\/ar\/products\/f-3330-hima-984333002-hiquad-safety-plc-digital-output-module-24vdc","provider":"SpareOil Automation","version":"1.0","type":"link"}