{"product_id":"ge-fanuc-ic693bem330-series-90-30-fip-bus-interface-module","title":"GE Fanuc IC693BEM330 Series 90-30 FIP Bus Interface Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC693BEM330\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC693BEM330\u003c\/strong\u003e FIP I\/O Scanner, operates as a dedicated hardware component for distributed I\/O data processing within Series 90-30 and Series 90-70 platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693BEM330\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.69 lbs (0.31 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSingle-slot Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Limits (Refer to Manual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e609 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eFIP I\/O Scanner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eTwo (2) 9-pin D-shell female connectors; One (1) Synchro port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Rate\u003c\/td\u003e\n\u003ctd\u003e1 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Support\u003c\/td\u003e\n\u003ctd\u003eUniversal Backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 19 I\/O modules (across 2 baseplates)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol Support\u003c\/td\u003e\n\u003ctd\u003eFIP and WORLD FIP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSynchro Mating Connector\u003c\/td\u003e\n\u003ctd\u003eMolex #39-01-4031\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus LED Indicators\u003c\/td\u003e\n\u003ctd\u003eCD1, TEN1, CD2, TEN2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Inter-Backplane Scaling and Signal Profiles\u003c\/h3\u003e\n\u003cp\u003eThe module leverages a 1 MHz network transmission rate to establish deterministic I\/O density scaling across remote drops. High-velocity serialization logic updates and maps remote I\/O variables into the primary CPU application memory space during defined scan windows. To eliminate data jitter during high-density block transfers, the integrated synchronization loop matches the communication velocity profile directly to the system backplane clock.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the specific slot limitations for the IC693BEM330 inside the main baseplate?\u003c\/p\u003e\n\u003cp\u003eA: The module must be positioned exclusively in slot 1 of the CPU baseplate. Insertion into standard I\/O slots or expansion baseplate slots will prevent proper backplane bus communication velocity and initialization.\u003c\/p\u003e\n\u003cp\u003eQ: What physical interfaces are required for establishing the FIP network link and synchronization?\u003c\/p\u003e\n\u003cp\u003eA: The primary FIP network utilizes the two front-facing 9-pin D-shell female connectors. For network synchronization across remote drops, the dedicated Synchro port requires a mating Molex connector catalog number #39-01-4031.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Attachment:\u003c\/strong\u003e Ensure the module is properly aligned with the top and bottom chassis guides of slot 1 before pivoting the unit down into the backplane connector. Fasten the structural screw to secure grounding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing Constraints:\u003c\/strong\u003e Route the FIP network cables away from high-voltage AC lines and motor drive paths to avoid industrial electrical noise from disrupting the 1 MHz differential carrier signal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding:\u003c\/strong\u003e All FIP network cable shields must be grounded at defined points according to standard industrial field bus installation practices to prevent carrier detection errors on channels 1 and 2.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43627143626842,"sku":"IC693BEM330","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC693BEM330.png?v=1783655351","url":"https:\/\/www.spareoil.com\/ar\/products\/ge-fanuc-ic693bem330-series-90-30-fip-bus-interface-module","provider":"SpareOil Automation","version":"1.0","type":"link"}