{"product_id":"ge-fanuc-ic693mdr390-series-90-30-combination-i-o-module","title":"GE Fanuc IC693MDR390 Series 90-30 Combination I\/O Module","description":"\u003cp\u003eConfigured for discrete signal processing and relay load actuation in Series 90-30 platforms, the \u003cstrong\u003eGE Fanuc IC693MDR390\u003c\/strong\u003e (\u003cstrong\u003eIC693MDR390\u003c\/strong\u003e Combination Discrete Input\/Output Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693MDR390\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.69 lbs (0.31 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSingle-slot Series 90-30 module width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e80 mA backplane current draw (all I\/O active); 70 mA (all outputs energized)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 discrete DC inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Rated Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal (-30 to +32 VDC range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput On-State Limits\u003c\/td\u003e\n\u003ctd\u003e15 to 32 VDC; 4 mA minimum current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Off-State Limits\u003c\/td\u003e\n\u003ctd\u003e0 to 5 VDC; 1.5 mA maximum leakage current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e7.5 mA typical at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Response Time\u003c\/td\u003e\n\u003ctd\u003e7 ms typical (On and Off transitions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8 Normally Open (N.O.) relay contact outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Operating Voltage\u003c\/td\u003e\n\u003ctd\u003e5 to 30 VDC; 5 to 250 VAC (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Rating\u003c\/td\u003e\n\u003ctd\u003e2 A maximum per point; 4 A maximum per common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Response Time\u003c\/td\u003e\n\u003ctd\u003e15 ms maximum (On and Off transitions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 V RMS between logic\/inputs and outputs; 500 V RMS between output groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Diagnostics\u003c\/td\u003e\n\u003ctd\u003eIndividual status LED indicators per I\/O circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe IC693MDR390 module updates 8 discrete input states and 8 relay output channels across the backplane bus to optimize backplane bus communication velocity and I\/O density scaling within a single slot footprint. The input section processes 24 VDC signals with a 7 ms transition delay, while the output section features two isolated groups of four Normally Open relay contacts capable of switching up to 2 A per point across 5-30 VDC or 5-250 VAC line ranges. Internal firmware flash compatibility ensures seamless address mapping across baseplate configurations. High-density isolation rated at 1500 V RMS protects internal backplane logic from external load transients.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the electrical rating limits for the output relay contacts?\u003c\/p\u003e\n\u003cp\u003eA: Each Normally Open relay output channel supports up to 2 A maximum at operating voltages of 5 to 30 VDC or 5 to 250 VAC (50\/60 Hz), with a limit of 4 A maximum per common grouping.\u003c\/p\u003e\n\u003cp\u003eQ: How are the output channels grouped and isolated from one another?\u003c\/p\u003e\n\u003cp\u003eA: The 8 relay output contacts are arranged into two independent groups of 4 channels each, featuring 500 V RMS galvanic isolation between groups and 1500 V RMS isolation from field logic.\u003c\/p\u003e\n\u003cp\u003eQ: What is the backplane current draw for the IC693MDR390 during full operation?\u003c\/p\u003e\n\u003cp\u003eA: The module draws 80 mA from the backplane bus when all input and output channels are active, and 70 mA when only the output relays are energized.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDe-energize system backplane power and field voltage supply loops prior to installing or servicing the module.\u003c\/li\u003e\n\u003cli\u003eInsert the single-slot IC693MDR390 into any open I\/O slot of a Series 90-30 local, expansion, or remote baseplate, verifying that the edge connector aligns with the backplane bus.\u003c\/li\u003e\n\u003cli\u003eSecure the module top and bottom panel screws to establish chassis mechanical retention and earth grounding.\u003c\/li\u003e\n\u003cli\u003eConnect 24 VDC discrete input devices and AC\/DC output loads to the removable terminal block in accordance with the 2-group isolated wiring arrangement.\u003c\/li\u003e\n\u003cli\u003eSeparate DC input signal wiring from AC high-current load cables inside wireways to prevent inductive crosstalk, grounding shield connections at a single baseplate chassis point.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43737992331354,"sku":"IC693MDR390","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC693MDR390.png?v=1785133300","url":"https:\/\/www.spareoil.com\/ar\/products\/ge-fanuc-ic693mdr390-series-90-30-combination-i-o-module","provider":"SpareOil Automation","version":"1.0","type":"link"}