{"product_id":"ge-fanuc-ic695cep001-pacsystems-rx3i-cep-carrier-component","title":"GE Fanuc IC695CEP001 PACSystems RX3i CEP Carrier Component","description":"\u003cp\u003eConfigured for PROFINET network node interfacing in PACSystems RX3i platforms, the \u003cstrong\u003eGE Fanuc IC695CEP001\u003c\/strong\u003e (\u003cstrong\u003eIC695CEP001\u003c\/strong\u003e Compact Expansion Carrier) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC695CEP001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.38 lbs (0.62 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e177.2 x 51 x 35 mm (7 x 2 x 1.3 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C (32 to 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5.25 W (0.22 A) at 24 VDC nominal (Input Range: 19.2 to 30 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd\u003eDual RJ-45 copper 10\/100 Base-TX Ethernet ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET Version\u003c\/td\u003e\n\u003ctd\u003ePROFINET Version 2.3 (Class A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Interface\u003c\/td\u003e\n\u003ctd\u003e1 Micro-B USB 2.0 compliant port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capacity per Station\u003c\/td\u003e\n\u003ctd\u003e1 I\/O module per station; 1024 bytes total I\/O (512 bytes input \/ 512 bytes output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\/Status Bits\u003c\/td\u003e\n\u003ctd\u003e32 input status bits \/ 32 output control bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgramming Software\u003c\/td\u003e\n\u003ctd\u003eProficy Machine Edition 8.0 SIM 5 or later\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet Deterministic Networks and Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe IC695CEP001 integrates into Profinet deterministic networks to manage high-speed remote node scanning across ring, star, and line topologies. Featuring a built-in Micro-B USB 2.0 port, the carrier maintains complete firmware flash compatibility for local operating system upgrades without removing the module from field wiring. Dual RJ-45 copper Ethernet ports support 10\/100 Mbps auto-sensing data routing, ensuring deterministic packet transport, I\/O density scaling, and real-time synchronization between the central CPU and attached I\/O drop hardware.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What software version is required to configure the IC695CEP001 carrier module?\u003c\/p\u003e\n\u003cp\u003eA: The IC695CEP001 requires Proficy Machine Edition version 8.0 SIM 5 or later for system configuration, parameterization, and network setup.\u003c\/p\u003e\n\u003cp\u003eQ: How many I\/O modules can be mounted to a single IC695CEP001 CEP carrier station?\u003c\/p\u003e\n\u003cp\u003eA: Each IC695CEP001 carrier station supports exactly 1 RX3i I\/O module, handling up to 512 bytes of input data and 512 bytes of output data.\u003c\/p\u003e\n\u003cp\u003eQ: What is the purpose of the onboard Micro-B USB port on the IC695CEP001?\u003c\/p\u003e\n\u003cp\u003eA: The USB 2.0 Micro-B connector is dedicated to performing local maintenance tasks and updating module firmware.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect main line power supplying the 24 VDC field power bus before mounting or wiring the IC695CEP001 carrier.\u003c\/li\u003e\n\u003cli\u003eSecure the IC695CEP001 carrier to the mounting surface or DIN rail according to standard panel mechanical practices.\u003c\/li\u003e\n\u003cli\u003eConnect 24 VDC power conductors (19.2 to 30 VDC operating range) to the module power input terminals, maintaining correct wire polarity.\u003c\/li\u003e\n\u003cli\u003ePlug CAT5e or CAT6 industrial shielded Ethernet cables into the RJ-45 receptacles, verifying that cable drain wires are grounded to suppress noise.\u003c\/li\u003e\n\u003cli\u003eInstall the designated RX3i I\/O module into the carrier slot, applying power and confirming LED diagnostic indicators for active network status.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43778244378714,"sku":"IC695CEP001","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC695CEP001.png?v=1785736717","url":"https:\/\/www.spareoil.com\/ar\/products\/ge-fanuc-ic695cep001-pacsystems-rx3i-cep-carrier-component","provider":"SpareOil Automation","version":"1.0","type":"link"}