{"product_id":"ge-ic693cbl305-series-90-30-cable","title":"GE IC693CBL305 Series 90-30 Cable","description":"\u003cp\u003eThe \u003cstrong\u003eGE IC693CBL305\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC693CBL305\u003c\/strong\u003e Wye Communication Cable, operates as a dedicated hardware component for serial signal bifurcation within Series 90-30 platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693CBL305\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.25 lbs (0.11 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e30.5 cm (1 foot) total length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C (standard industrial range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0 W (passive component)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eWye Communication Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eSeries 90-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eCommunications Coprocessor (CMM \/ PCM) modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Material\u003c\/td\u003e\n\u003ctd\u003e28 AWG wire sizing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eContinuous wire shield protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e25-pin RS-232 \/ RS-485 interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Geometry\u003c\/td\u003e\n\u003ctd\u003eRight-angle master connector to dual labelled branch connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFirmware Flash Compatibility and Serial Routing Stability\u003c\/h3\u003e\n\u003cp\u003eWhile functioning as a passive electrical interface, this cable supports high-velocity serial links used during system initialization and firmware flash compatibility runs across adjacent CMM or PCM modules. The internal 28 AWG conductors maintain precise signal impedance boundaries required for non-deterministic backplane bus communication velocity and serial diagnostic configurations, preventing signal attenuation across both separated communication channels.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What specific hardware interfaces are exposed by this cable assembly?\u003c\/p\u003e\n\u003cp\u003eA: The single combined port on the CMM or PCM coprocessor module is split into two distinct physical electrical lines. Port 1 is dedicated to routing RS-232 serial signals, whereas Port 2 routes either RS-232 or RS-485 serial signal protocols to separate 25-pin connector ends.\u003c\/p\u003e\n\u003cp\u003eQ: Can this cable be hot-plugged while active communication is occurring?\u003c\/p\u003e\n\u003cp\u003eA: No. Plugging or unplugging the passive cable during active serial data transmission will interrupt the electrical circuit loop, resulting in immediate communication frame errors, timeout faults, or data corruption flags within the host controller software module.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Routing\u003c\/strong\u003e: Connect the right-angle master housing directly to the combined port on the coprocessor module. Secure the captive physical mounting screws to prevent tension or accidental disconnection from vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding Ground Continuity\u003c\/strong\u003e: Ensure the wire shield layer integrated into the cable assembly remains intact and uncompromised during installation to preserve continuous Faraday cage coverage across the RS-232 and RS-485 paths.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBend Radius Limits\u003c\/strong\u003e: Observe standard industrial copper wiring guidelines; do not exceed sharp physical bending parameters near the right-angle molding or the split Y-junction block.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43616489832538,"sku":"IC693CBL305","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC693CBL305.png?v=1783481020","url":"https:\/\/www.spareoil.com\/ar\/products\/ge-ic693cbl305-series-90-30-cable","provider":"SpareOil Automation","version":"1.0","type":"link"}