{"product_id":"ge-ic693ptm101-series-90-30-power-transducer-module","title":"GE IC693PTM101 Series 90-30 Power Transducer Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE IC693PTM101\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC693PTM101\u003c\/strong\u003e Power Transducer Module, operates as a dedicated hardware component for electrical power parameter calculation and RMS signal monitoring within Series 90-30 PLC backplane networks. The assembly consists of a processing module, an interface board, and an IC693CBL340 interface cable, accepting direct potential transformer and current transformer inputs to compute real-time electrical metrics.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693PTM101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSeries 90-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePower Transducer Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSub-Assembly Components\u003c\/td\u003e\n\u003ctd\u003eProcessing module, interface board, IC693CBL340 cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e10 VAC to 120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current Range\u003c\/td\u003e\n\u003ctd\u003e0 A to 7.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Frequency\u003c\/td\u003e\n\u003ctd\u003e35 Hz to 70 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasured Parameters\u003c\/td\u003e\n\u003ctd\u003eVoltage, Current, kW, kVAR, kVA, kWH, kVARH, kVAH, Power Factor, Frequency, Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Resolution\u003c\/td\u003e\n\u003ctd\u003e14-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalculation Speed\u003c\/td\u003e\n\u003ctd\u003e20 ms at 50 Hz; 16.67 ms at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Modes\u003c\/td\u003e\n\u003ctd\u003eSingle mode, 3-phase mode, Synchro monitor mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Allocation\u003c\/td\u003e\n\u003ctd\u003e%I: 16 bits; %Q: 16 bits; %AI: 25 words; %AQ: 2 words\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Power Consumption\u003c\/td\u003e\n\u003ctd\u003e400 mA maximum at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e4 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eAny standard Series 90-30 baseplate slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Series 90-30 single-slot footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.63 kg (8.00 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Interfacing and Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe IC693PTM101 processes raw transformer waveforms through a 14-bit analog stage and transmits RMS calculated values over the backplane bus. Utilizing high backplane bus communication velocity, the processing module updates CPU register memory (%I, %Q, %AI, and %AQ) every 16.67 ms (at 60 Hz) or 20 ms (at 50 Hz). Galvanic isolation of 1500 VAC between field transformer connections and the 5 VDC backplane bus maintains signal integrity and preserves firmware flash compatibility across local, expansion, and remote baseplate configurations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What memory mapping registers are allocated in the Series 90-30 CPU for the IC693PTM101?\u003c\/p\u003e\n\u003cp\u003eA: The module reserves 16 discrete input bits (%I), 16 discrete output bits (%Q), 25 analog input words (%AI), and 2 analog output words (%AQ) in the controller memory map.\u003c\/p\u003e\n\u003cp\u003eQ: What operating modes can be configured on the IC693PTM101?\u003c\/p\u003e\n\u003cp\u003eA: The module can be programmed via software to run in Single mode, 3-Phase mode (Wye or Delta configurations), or Synchro Monitor mode for generator-to-grid synchronization monitoring.\u003c\/p\u003e\n\u003cp\u003eQ: What backplane power current draw does the processing module require?\u003c\/p\u003e\n\u003cp\u003eA: The IC693PTM101 draws a maximum of 400 mA at 5 VDC directly from the Series 90-30 backplane power supply, with total power dissipation capped at 4 W.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eIsolate primary rack power and disconnect external CT\/PT secondary circuits prior to mounting or servicing the hardware.\u003c\/li\u003e\n\u003cli\u003eWear an ESD grounding wrist strap clamped to an unpainted enclosure chassis frame to prevent static discharge to the processing card.\u003c\/li\u003e\n\u003cli\u003eInstall the processing module into any available Series 90-30 baseplate slot and seat the interface board near the transformer terminal block.\u003c\/li\u003e\n\u003cli\u003eInterconnect the processing module and interface board using the provided IC693CBL340 cable, tightening retaining screws at both ports.\u003c\/li\u003e\n\u003cli\u003eConnect input signals within 10 to 120 VAC and 0 to 7.5 A limits, ensuring transformer shields and enclosure metalwork are firmly earth-grounded.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43787753947226,"sku":"IC693PTM101","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC693PTM101.jpg?v=1785921140","url":"https:\/\/www.spareoil.com\/ar\/products\/ge-ic693ptm101-series-90-30-power-transducer-module","provider":"SpareOil Automation","version":"1.0","type":"link"}