{"product_id":"ge-ic694alg391-rx3i-pacsystem-analog-output-module","title":"GE IC694ALG391 RX3i PACSystem Analog Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE IC694ALG391\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC694ALG391\u003c\/strong\u003e Analog Output Module, operates as a dedicated hardware component for field signal generation within PACSystems RX3i platforms. The unit converts internal controller logic values into 2 channels of analog current or voltage signals (1-5 VDC, 0-5 VDC, 0-20 mA, or 4-20 mA) using a 12-bit digital-to-analog converter.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC694ALG391\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003ePACSystems RX3i\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e2 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Ranges\u003c\/td\u003e\n\u003ctd\u003e1-5 VDC, 0-5 VDC, 0-20 mA, 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard backplane power allocation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003ePanel mount or DIN rail via baseplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSingle-slot RX3i module footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.29 kg (0.64 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Interfacing and Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe IC694ALG391 module interfaces directly with the PACSystems RX3i backplane bus to transfer command values from the CPU to its onboard digital-to-analog conversion circuits. Utilizing high backplane bus communication velocity, output values update deterministically during each controller scan cycle. Built-in firmware flash compatibility preserves system messaging integrity and ensures synchronized signal updates across expanded local or remote RX3i baseplate racks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What output signal ranges can be configured on the IC694ALG391?\u003c\/p\u003e\n\u003cp\u003eA: The module supports software configuration for both voltage (1-5 VDC, 0-5 VDC) and current (0-20 mA, 4-20 mA) field outputs across its 2 channels.\u003c\/p\u003e\n\u003cp\u003eQ: How is the IC694ALG391 physically mounted in a system?\u003c\/p\u003e\n\u003cp\u003eA: The module installs directly into any standard single slot of an RX3i baseplate, which supports panel or DIN rail chassis mounting inside an industrial enclosure.\u003c\/p\u003e\n\u003cp\u003eQ: What resolution does the internal D\/A converter provide for field control signals?\u003c\/p\u003e\n\u003cp\u003eA: The onboard digital-to-analog converter operates at a 12-bit resolution across all configured voltage and current ranges.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect main backplane rack power and field loop power sources before inserting or removing the module.\u003c\/li\u003e\n\u003cli\u003eFasten an ESD wrist strap to a grounded metal enclosure framework prior to handling the module assembly.\u003c\/li\u003e\n\u003cli\u003eAlign the module with the card guides of the target RX3i baseplate slot and press firmly until the locking tab fully engages.\u003c\/li\u003e\n\u003cli\u003eWire output field devices using shielded twisted-pair cables, grounding the cable shield drain wire at a single point near the enclosure earth terminal.\u003c\/li\u003e\n\u003cli\u003eApply system power and confirm through status LEDs that the card undergoes initialization without channel fault reports.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43787783733338,"sku":"IC694ALG391","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC694ALG391.jpg?v=1785922143","url":"https:\/\/www.spareoil.com\/ar\/products\/ge-ic694alg391-rx3i-pacsystem-analog-output-module","provider":"SpareOil Automation","version":"1.0","type":"link"}