{"product_id":"ge-ic697mdl250-series-90-70-discrete-input-module","title":"GE IC697MDL250 Series 90-70 Discrete Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE IC697MDL250\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC697MDL250\u003c\/strong\u003e Discrete Input Module, operates as a dedicated hardware component for 120 VAC discrete signal sensing within Series 90-70 backplane platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC697MDL250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.75 kg (1.65 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard single-slot Series 90-70 module format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.75 W maximum (0.35 A @ 5 VDC backplane bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Points\u003c\/td\u003e\n\u003ctd\u003e32 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Groups\u003c\/td\u003e\n\u003ctd\u003e4 isolated groups (8 points per group)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Filter Delay\u003c\/td\u003e\n\u003ctd\u003e20 ms filter delay time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Load\u003c\/td\u003e\n\u003ctd\u003e0.35 A from internal 5 VDC bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; I\/O Processing\u003c\/h3\u003e\n\u003cp\u003eThe module maintains synchronized input scanning across the Series 90-70 backplane bus, supporting deterministic backplane bus communication velocity during high-density signal transitions. Software configuration capabilities provide channel parameter assignment and I\/O density scaling across the 32 input points, eliminating the need for physical jumpers or DIP switch settings.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What current load does the IC697MDL250 place on the 5 VDC backplane supply?\u003c\/p\u003e\n\u003cp\u003eA: The module draws 0.35 A from the internal +5 VDC backplane power bus.\u003c\/p\u003e\n\u003cp\u003eQ: What is the channel group isolation configuration on this module?\u003c\/p\u003e\n\u003cp\u003eA: The 32 discrete input points are divided into 4 optically isolated groups, containing 8 points per group.\u003c\/p\u003e\n\u003cp\u003eQ: What is the input filter delay response time for signal conditioning?\u003c\/p\u003e\n\u003cp\u003eA: The module utilizes a standard 20 ms input filter delay time for field signal debouncing.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaseplate Mounting:\u003c\/strong\u003e De-energize system power before inserting the module into any available Series 90-70 baseplate slot, pressing firmly until the module backplane connectors seat fully into the bus frame.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Wiring Connections:\u003c\/strong\u003e Wire 120 VAC field inputs to the removable terminal block, ensuring each isolated group of 8 points receives its dedicated neutral and supply line connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeparation of Lines:\u003c\/strong\u003e Maintain clear physical separation between high-voltage 120 VAC input lines and low-voltage DC communication or logic cabling inside the wireway.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding:\u003c\/strong\u003e Secure field wiring cable shields and baseplate grounding studs directly to a low-impedance master enclosure ground point to prevent noise coupling.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43683914350682,"sku":"IC697MDL250","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC697MDL250.png?v=1784600702","url":"https:\/\/www.spareoil.com\/ar\/products\/ge-ic697mdl250-series-90-70-discrete-input-module","provider":"SpareOil Automation","version":"1.0","type":"link"}