{"product_id":"ge-ic697mdl650-series-90-70-discrete-input-module","title":"GE IC697MDL650 Series 90-70 Discrete Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE IC697MDL650\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC697MDL650\u003c\/strong\u003e Discrete Input Module, operates as a dedicated hardware component for 24 VDC positive logic digital signal sensing within Series 90-70 backplane platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC697MDL650\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.94 kg (2.06 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard single-slot Series 90-70 module format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.5 W maximum (0.3 A from internal 5 VDC backplane bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003e32 positive logic (sinking\/sourcing field device compatibility)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Isolation Groups\u003c\/td\u003e\n\u003ctd\u003e4 groups (8 points per group)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e-3 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e10 mA at rated 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter Capabilities\u003c\/td\u003e\n\u003ctd\u003eSelectable input filter time constants\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus LED Indicators\u003c\/td\u003e\n\u003ctd\u003eIndividual input point activity LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Velocity \u0026amp; Deterministic I\/O Processing\u003c\/h3\u003e\n\u003cp\u003eThe module supports real-time I\/O scan execution across the Series 90-70 VME backplane architecture, maintaining optimal backplane bus communication velocity and deterministic I\/O updates. Software-configurable software addressing removes physical jumper configurations, ensuring software compatibility across system backplane expansion slots.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What current draw does the IC697MDL650 place on the internal 5 VDC backplane bus?\u003c\/p\u003e\n\u003cp\u003eA: The module requires 0.3 A from the 5 VDC backplane power rail.\u003c\/p\u003e\n\u003cp\u003eQ: How are the 32 input points grouped on the IC697MDL650?\u003c\/p\u003e\n\u003cp\u003eA: The 32 inputs are divided into 4 isolated groups, with each group containing 8 discrete input points.\u003c\/p\u003e\n\u003cp\u003eQ: Are physical DIP switches or jumpers required to set the I\/O base addresses on this module?\u003c\/p\u003e\n\u003cp\u003eA: No physical DIP switches or jumpers are required; I\/O reference addresses are configured through system software utilities.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Insertion:\u003c\/strong\u003e Align the module card edges with the Series 90-70 rack guide slots and press firmly until the backplane connectors seat completely, then lock the top and bottom latch levers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring:\u003c\/strong\u003e Land 24 VDC discrete signal wires on the terminal block, maintaining clear separation between field DC power wiring and high-voltage AC cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProximity Switch Wiring:\u003c\/strong\u003e When wiring 3-wire DC proximity switches, ensure the sensor output meets the minimum off-state voltage threshold (-3 VDC) and on-state current specification (10 mA at 24 VDC).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Terminate cable shields at the rack ground lug or grounding bar to prevent high-frequency field noise from corrupting input state transitions.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43683841146970,"sku":"IC697MDL650","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC697MDL650.png?v=1784599662","url":"https:\/\/www.spareoil.com\/ar\/products\/ge-ic697mdl650-series-90-70-discrete-input-module","provider":"SpareOil Automation","version":"1.0","type":"link"}