{"product_id":"ge-ic697pwr710-series-90-70-power-supply-module","title":"GE IC697PWR710 Series 90-70 Power Supply Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE IC697PWR710\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC697PWR710\u003c\/strong\u003e Power Supply Module, operates as a dedicated hardware component for backplane power generation within Series 90-70 platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC697PWR710\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.00 lbs (1.36 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Series 90-70 single-slot plug-in profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C (Standard industrial range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e90 W maximum input power at full load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Options\u003c\/td\u003e\n\u003ctd\u003e90-264 VAC (47-63 Hz) or 100-150 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Inrush Current\u003c\/td\u003e\n\u003ctd\u003e3 A peak typical (half-cycle duration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor Correction\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 0.95 via integrated active PFC circuitry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Power\u003c\/td\u003e\n\u003ctd\u003e56 W maximum total output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal DC Output\u003c\/td\u003e\n\u003ctd\u003e5.1 VDC (Up to 11 A available on the +5 VDC rail)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e4.90 to 5.25 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Limit\u003c\/td\u003e\n\u003ctd\u003e6.2 V typical (electronic clamping protection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvercurrent Limit\u003c\/td\u003e\n\u003ctd\u003e12 A typical (electronic foldback current limit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRide-Through Duration\u003c\/td\u003e\n\u003ctd\u003e21 ms minimum (at complete loss of nominal AC input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVME Architecture\u003c\/td\u003e\n\u003ctd\u003eCompatible with VME standard C.1 specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Assignment\u003c\/td\u003e\n\u003ctd\u003eLeftmost slot of standard IC697 or VME racks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe module supplies regulated 5.1 VDC power lines across the chassis backplane bus, sustaining the voltage stability needed to maintain high-speed backplane bus communication velocity during intensive CPU sweep intervals. Active power factor correction circuits minimize harmonic distortion across the input lines. Internal logic monitors the power rails, signaling early status alerts to the host controller prior to the expiration of the 21 ms ride-through window, enabling safe processor state preservation and firmware flash compatibility interlocks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the overvoltage and overcurrent protection behave during a field fault?\u003c\/p\u003e\n\u003cp\u003eA: The module utilizes non-destructive electronic clamping circuits. If the 5.1 VDC rail climbs to 6.2 V, the overvoltage loop clamps the output. Under overcurrent states approaching 12 A, the output voltage drops automatically. Both mechanisms protect the internal power supply fuse from opening, recovering to nominal values immediately after the field load anomaly is removed.\u003c\/p\u003e\n\u003cp\u003eQ: Can this power supply module drive multiple racks simultaneously?\u003c\/p\u003e\n\u003cp\u003eA: Yes. It can drive a secondary expansion rack through specialized extension cables (IC697CBL700 \/ IC697CBL713) provided that the auxiliary chassis requires only 5 VDC logic power and the combined current demands of both racks remain within the 56 W maximum output thresholds.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Placement\u003c\/strong\u003e: Slide the module into the leftmost slot of an authorized IC697 rack frame or a VME integrator rack. Ensure that the module's backplane connector aligns perfectly before locking it into position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Configuration\u003c\/strong\u003e: Connect a dedicated AWG #12 (3.3 mm2) copper grounding conductor to the module's front ground screw terminal. Tighten the wire lug screw to a maximum torque rating of 12 in-lb (1.3 N-m).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Requirements\u003c\/strong\u003e: Use only copper supply conductors rated for a minimum temperature of 75 deg C. Route the incoming high-voltage AC or DC lines inside separate conduits away from sensitive low-level analog or communication cables.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43616560283738,"sku":"IC697PWR710","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC697PWR710.png?v=1783482549","url":"https:\/\/www.spareoil.com\/ar\/products\/ge-ic697pwr710-series-90-70-power-supply-module","provider":"SpareOil Automation","version":"1.0","type":"link"}