{"product_id":"ge-series-90-70-high-speed-counter-module-ic697hsc700","title":"GE Series 90-70 High-Speed Counter Module | IC697HSC700","description":"\u003cp\u003eConfigured for high-frequency pulse calculation and discrete tracking in industrial systems, the \u003cstrong\u003eGE IC697HSC700\u003c\/strong\u003e (\u003cstrong\u003eIC697HSC700\u003c\/strong\u003e High-Speed Counter Module) provides direct physical\/electrical execution for tracking rapid pulse streams independent of standard PLC CPU processing sweeps.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC697HSC700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.38 lbs (0.62 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSingle-slot module for Series 90-70 baseplates\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.0 A at 5 VDC from backplane (plus 10 mA per active output channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic Inputs\u003c\/td\u003e\n\u003ctd\u003e12 single-ended or differential circuits (5 VDC or 10-30 VDC operating range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Outputs\u003c\/td\u003e\n\u003ctd\u003e4 Positive Logic output points (10-30 VDC rated at 20 mA maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Frequency\u003c\/td\u003e\n\u003ctd\u003e200 kHz (Counter Types A, D, and E in Up\/Down Quad mode); 800 kHz (Type E in Quad B mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Filters\u003c\/td\u003e\n\u003ctd\u003eSelectable high-frequency filter (200 kHz) or low-frequency filter (30 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Rating\u003c\/td\u003e\n\u003ctd\u003e1500 V for 1 second duration, 30 VAC\/VDC continuous steady-state\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003e1 x MODULE OK LED, 4 x Output circuit status LEDs (01-04)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirmware Dependency\u003c\/td\u003e\n\u003ctd\u003eRequires Series 90-70 CPU with firmware version 5.0 or later\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe module executes direct high-speed sub-rack calculations, maximizing input signal registration up to 800 kHz without penalizing backplane bus communication velocity. Integrated ladder interrupt commands process real-time events immediately upon hitting target counter presets. Physical parameter tables and counting profiles match firmware flash compatibility guidelines across automated Windows-based configurations via Proficy Machine Edition or legacy MS-DOS utility tools, ensuring synchronous execution alongside the main rack processor.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the IC697HSC700 process magnetic pickup inputs directly?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The hardware includes internal conditioning circuitry that accepts high-frequency magnetic pickup signals. It converts low-amplitude sinusoidal waveforms into digital pulse trains using 5 selectable counter types (Types A through E) for velocity measurement and turbine flowmeter tracking.\u003c\/p\u003e\n\u003cp\u003eQ: How are the 4 positive logic outputs powered and protected?\u003c\/p\u003e\n\u003cp\u003eA: The 4 control output circuits require an external, user-supplied 5 VDC or 10-30 VDC power supply connection. These solid-state outputs feature integrated electronic short-circuit protection circuits that isolate individual loops during field fault spikes.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaseplate Positioning\u003c\/strong\u003e: Isolate the power supply to the rack frame before installation. Slide the module into any available I\/O slot inside the CPU baseplate, local expansion rack, or remote baseplate structure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding Protocols\u003c\/strong\u003e: Route all high-frequency signal lines through twisted-shielded pair cables. Terminate the shield wires directly at the central enclosure grounding bar to suppress parasitic field noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFilter Configuration\u003c\/strong\u003e: Select the internal low-frequency filter (30 Hz) for mechanical switch or limit switch inputs to eliminate physical contact bounce, and use the high-frequency path (200 kHz \/ 800 kHz) only for solid-state encoder sensors.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43616567099482,"sku":"IC697HSC700","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC697HSC700.png?v=1783482893","url":"https:\/\/www.spareoil.com\/ar\/products\/ge-series-90-70-high-speed-counter-module-ic697hsc700","provider":"SpareOil Automation","version":"1.0","type":"link"}