{"product_id":"honeywell-10310-3-1-earth-leakage-detector","title":"Honeywell 10310\/3\/1 Electronic Earth Leakage Detector","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Honeywell 10310\/3\/1 is an electronic earth leakage detector designed for industrial safety and monitoring applications. This module provides reliable earth fault detection, ensuring operational integrity within control systems by monitoring for leakage currents that exceed defined safety thresholds. It is engineered for integration into standard control environments requiring precise fault detection and reporting.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eElectronic earth fault detection with a set threshold of 5.5 mA (± 1 mA).\u003c\/li\u003e\n\u003cli\u003eDesigned for 24 V DC supply voltage operation.\u003c\/li\u003e\n\u003cli\u003eIntegrated reset input functionality supporting a range of 18 - 70 V DC.\u003c\/li\u003e\n\u003cli\u003eHigh isolation rating of 1500 V DC \/ 1000 V AC to protect sensitive circuitry.\u003c\/li\u003e\n\u003cli\u003eCompact module design suitable for industrial panel mounting.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e10310\/3\/1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEarth Fault Threshold\u003c\/td\u003e\n\u003ctd\u003e5.5 mA (± 1 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReset Input Voltage\u003c\/td\u003e\n\u003ctd\u003e18 - 70 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReset Input Current\u003c\/td\u003e\n\u003ctd\u003e1.1 mA at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Earth Current\u003c\/td\u003e\n\u003ctd\u003e25 - 32 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Output Current\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Output Voltage\u003c\/td\u003e\n\u003ctd\u003e36 V DC \/ 30 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInitial Contact Resistance\u003c\/td\u003e\n\u003ctd\u003e30 mOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-5 degC to +50 degC (23 degF to +122 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the module is installed in a clean, dry environment within an appropriately rated industrial enclosure.\u003c\/li\u003e\n\u003cli\u003eVerify that the supply voltage matches the 24 V DC requirement before powering on the unit.\u003c\/li\u003e\n\u003cli\u003eMaintain proper clearance around the module to allow for adequate heat dissipation during operation.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for input and output connections to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eAlways disconnect power before performing any wiring, inspection, or maintenance on the module to prevent electrical shock or damage to the device.\u003c\/li\u003e\n\u003cli\u003eEnsure all terminals are tightened to the correct torque to prevent loose connections, which can lead to increased contact resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the Honeywell 10310\/3\/1?\u003c\/h3\u003e\u003cp\u003eThis module serves as an electronic earth leakage detector, specifically designed to monitor for earth faults and provide a signal when the current exceeds a 5.5 mA threshold.\u003c\/p\u003e\u003ch3\u003eCan this device be reset remotely?\u003c\/h3\u003e\u003cp\u003eYes, the module features a reset input that accepts a voltage range of 18 - 70 V DC, allowing for remote reset capabilities within your control system.\u003c\/p\u003e\u003ch3\u003eWhat is the operating temperature range for this unit?\u003c\/h3\u003e\u003cp\u003eThe device is designed to operate reliably in temperatures between -5 degC and +50 degC (23 degF to +122 degF).\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44012812238938,"sku":"10310\/3\/1","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_1cb7cd87-3fad-42c8-a426-085b851820ce.jpg?v=1788582352","url":"https:\/\/www.spareoil.com\/ar\/products\/honeywell-10310-3-1-earth-leakage-detector","provider":"SpareOil Automation","version":"1.0","type":"link"}