{"product_id":"honeywell-cc-paoh01-51405039-175-hart-analog-output-module","title":"Honeywell CC-PAOH01 51405039-175 Analog Output Module","description":"\u003cp\u003eThe Honeywell CC-PAOH01 (51405039-175) is a 16-channel high-level analog output module engineered for the Experion PKS Series C I\/O platform. This module provides precise 4-20 mA current signals and integrates HART communication capabilities, allowing for seamless management of intelligent field devices such as smart valves and actuators.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16-channel high-level analog output configuration.\u003c\/li\u003e\n\u003cli\u003eIntegrated HART communication for advanced device diagnostics and multivariable data collection.\u003c\/li\u003e\n\u003cli\u003eConfigurable FAILOPT settings allow for per-channel safe-state behavior (Hold Last Value or Shed to Safe Value).\u003c\/li\u003e\n\u003cli\u003eEnhanced reliability with output read-back and automatic alarm annunciation on channel discrepancy.\u003c\/li\u003e\n\u003cli\u003eExtensive self-diagnostic routines to ensure process integrity.\u003c\/li\u003e\n\u003cli\u003eSupports redundant configurations to minimize process downtime during switchovers.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eActuator and valve positioning for precise process flow regulation.\u003c\/li\u003e\n\u003cli\u003eVariable speed drive control for motor and pump management.\u003c\/li\u003e\n\u003cli\u003eIntegration with smart HART-enabled field instrumentation.\u003c\/li\u003e\n\u003cli\u003eSequential and combustion control in power and energy sectors.\u003c\/li\u003e\n\u003cli\u003eHeavy industrial manufacturing, including steel production and smelting.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-PAOH01 (51405039-175)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Range\u003c\/td\u003e\n\u003ctd\u003e0 mA, 2.9 mA to 21.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.05% of Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibrated Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.35% of Full Scale (at 25 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Resistive Load\u003c\/td\u003e\n\u003ctd\u003e800 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Compliance Voltage\u003c\/td\u003e\n\u003ctd\u003e16 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Ripple\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 100 mV peak-to-peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Drift\u003c\/td\u003e\n\u003ctd\u003e0.005% of Full Scale\/degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThe CC-PAOH01 is designed for use with a dedicated Series C Input\/Output Termination Assembly (IOTA). Ensure the IOTA is securely mounted before installing the module.\u003c\/li\u003e\n\u003cli\u003eAlways power down the IOTA before inserting or removing the module to prevent electrical arcing or damage to the backplane connectors.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the IOTA to reduce electromagnetic interference (EMI) and protect signal integrity.\u003c\/li\u003e\n\u003cli\u003eRoute field wiring in accordance with local electrical codes, keeping signal cables separated from high-voltage power lines.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is fully seated and the locking mechanism is engaged to ensure a stable connection to the IOTA.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the CC-PAOH01?\u003c\/h3\u003e\u003cp\u003eThe CC-PAOH01 is a 16-channel analog output module designed to convert digital control signals into 4-20 mA current outputs for field devices, with added HART protocol support for smart communication.\u003c\/p\u003e\u003ch3\u003eWhat is the role of the IOTA?\u003c\/h3\u003e\u003cp\u003eThe IOTA (Input\/Output Termination Assembly) serves as the base for the Series C module, providing the necessary field wiring terminals and power distribution, eliminating the need for separate marshalling hardware.\u003c\/p\u003e\u003ch3\u003eHow does the module handle signal failures?\u003c\/h3\u003e\u003cp\u003eThe module features configurable FAILOPT parameters. In the event of an IOM electronics failure, the output will transition to a pre-configured safe state to maintain process safety.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43988995342426,"sku":"CC-PAOH01 51405039-175","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_6e4d6a9c-77c2-4fc2-94da-363f75a5c447.jpg?v=1788285092","url":"https:\/\/www.spareoil.com\/ar\/products\/honeywell-cc-paoh01-51405039-175-hart-analog-output-module","provider":"SpareOil Automation","version":"1.0","type":"link"}