{"product_id":"ic693mdl241-ge-fanuc-series-90-30-discrete-input-module","title":"IC693MDL241 GE Fanuc Series 90-30 Discrete Input Module","description":"\u003cp\u003eConfigured for field contact status sensing and discrete signal acquisition in Series 90-30 platforms, the \u003cstrong\u003eGE Fanuc IC693MDL241\u003c\/strong\u003e (\u003cstrong\u003eIC693MDL241\u003c\/strong\u003e Discrete Input Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693MDL241\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.69 lbs (0.31 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSingle-slot Series 90-30 module width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e80 mA at 5 VDC (all inputs active); 125 mA from isolated 24 VDC backplane bus or external user supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 discrete input channels (single group of 16 inputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VAC \/ 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0 to +30 VDC or 0 to +30 VAC (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Configuration\u003c\/td\u003e\n\u003ctd\u003ePositive \/ Negative logic (sink \/ source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Voltage\u003c\/td\u003e\n\u003ctd\u003e11.5 to 30.0 VAC \/ VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Voltage\u003c\/td\u003e\n\u003ctd\u003e0 to 4 VAC \/ VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Current\u003c\/td\u003e\n\u003ctd\u003e3.2 mA minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Current\u003c\/td\u003e\n\u003ctd\u003e1 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e7 mA at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Times\u003c\/td\u003e\n\u003ctd\u003eOn response: 12 ms maximum; Off response: 28 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 V RMS (1500 VAC) between field side and logic side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic Reading\u003c\/td\u003e\n\u003ctd\u003e%I memory table\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Indicators\u003c\/td\u003e\n\u003ctd\u003e16 green status LEDs (2 rows of 8: A1-A8, B1-B8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe IC693MDL241 input module updates discrete channel data into the CPU %I logic memory map across the backplane bus within a 12 ms On-response and 28 ms Off-response delay. Optimized for backplane bus communication velocity and I\/O density scaling, the 16-point single-group topology supports positive or negative logic in DC mode, as well as 50\/60 Hz AC signals. Logic-side circuits draw 80 mA from the 5 VDC backplane bus when all channels are active, while field power consumes 125 mA from the isolated 24 VDC bus or a user-provided power supply. Galvanic isolation of 1500 V RMS protects the internal backplane logic from external field circuit spikes.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What power sources can be used to supply the input field circuits on the IC693MDL241?\u003c\/p\u003e\n\u003cp\u003eA: Field circuits can be powered using an external 24 VAC\/VDC user supply or the isolated 24 VDC output supplied directly by the baseplate power supply.\u003c\/p\u003e\n\u003cp\u003eQ: What are the logic threshold limits for detecting On and Off channel states?\u003c\/p\u003e\n\u003cp\u003eA: The module registers an On-state at 11.5 to 30.0 VAC\/VDC (3.2 mA minimum) and an Off-state at 0 to 4 VAC\/VDC (1 mA maximum off-state current).\u003c\/p\u003e\n\u003cp\u003eQ: What are the backplane current draw requirements for this 16-point input module?\u003c\/p\u003e\n\u003cp\u003eA: The module consumes 80 mA from the 5 VDC backplane bus when all 16 inputs are ON, plus 125 mA from the isolated 24 VDC backplane supply or external user source.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eRemove primary power from the Series 90-30 baseplate and field power distribution loops before inserting or servicing the module.\u003c\/li\u003e\n\u003cli\u003eAlign the module chassis with the target slot on a 5-slot or 10-slot Series 90-30 baseplate and push until the backplane connector engages fully.\u003c\/li\u003e\n\u003cli\u003eTighten the top panel mounting screw to secure mechanical holding and establish solid chassis earth grounding.\u003c\/li\u003e\n\u003cli\u003eRoute field contact wiring (limit switches, pushbuttons, proximity sensors) to the terminal block, ensuring AC or DC voltage levels stay within the 0 to 30 V range.\u003c\/li\u003e\n\u003cli\u003eSeparate low-voltage input conductors from high-voltage AC lines to minimize noise coupling, grounding all cable shielding at a single frame terminal.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43737953108058,"sku":"IC693MDL241","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC693MDL241.png?v=1785132925","url":"https:\/\/www.spareoil.com\/ar\/products\/ic693mdl241-ge-fanuc-series-90-30-discrete-input-module","provider":"SpareOil Automation","version":"1.0","type":"link"}