{"product_id":"ic693mdl340-series-90-30-discrete-output-module-ge-fanuc","title":"IC693MDL340 Series 90-30 Discrete Output Module | GE Fanuc","description":"\u003cp\u003eThe \u003cstrong\u003eGE IC693MDL340\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC693MDL340\u003c\/strong\u003e Discrete Output Module, operates as a dedicated hardware component for 120 VAC load actuation within Series 90-30 PLC platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693MDL340\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg (1.00 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSingle-slot Series 90-30 module format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e315 mA from internal +5 VDC bus (all outputs ON)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Points\u003c\/td\u003e\n\u003ctd\u003e16 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Grouping\u003c\/td\u003e\n\u003ctd\u003e2 isolated groups (8 channels per group with 1 common)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC nominal (85 to 132 VAC range, 50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current per Point\u003c\/td\u003e\n\u003ctd\u003e0.5 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current per Group\u003c\/td\u003e\n\u003ctd\u003e3.0 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Load Current\u003c\/td\u003e\n\u003ctd\u003e50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inrush Current\u003c\/td\u003e\n\u003ctd\u003e20 A for one cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Response Time\u003c\/td\u003e\n\u003ctd\u003eON delay: 1 ms max; OFF delay: 1\/2 cycle max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Drop \/ Leakage\u003c\/td\u003e\n\u003ctd\u003e1.5 VAC max drop; 2 mA max leakage at 120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Rating\u003c\/td\u003e\n\u003ctd\u003e1500 V field-to-logic; 500 V group-to-group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Network Execution\u003c\/h3\u003e\n\u003cp\u003eThe module processes discrete logic execution commands received over the backplane bus to control connected field actuators. System-level backplane bus communication velocity guarantees deterministic scan updating, while onboard LED diagnostics provide per-channel status feedback and blown-fuse indication for physical loop verification.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the backplane current draw for the IC693MDL340 module? A: The module consumes 315 mA from the +5 VDC backplane supply when all 16 output channels are in the ON state.\u003c\/p\u003e\n\u003cp\u003eQ: What are the output current limitations per point and per group? A: Each individual output channel handles up to 0.5 A, while each 8-channel group supports a maximum continuous current load of 3.0 A.\u003c\/p\u003e\n\u003cp\u003eQ: How is galvanic isolation structured across the output circuits? A: The module provides 1500 V isolation between field-side circuits and logic-side backplane electronics, and 500 V isolation between the two independent output groups.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaseplate Slot Insertion:\u003c\/strong\u003e De-energize backplane power prior to inserting or removing the module from the Series 90-30 baseplate to protect edge connector contacts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Output Line Wiring:\u003c\/strong\u003e Wire 120 VAC field power to the group commons on the terminal block. Ensure total current per group does not exceed 3.0 A continuous load.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductive Load Suppression:\u003c\/strong\u003e Install metal oxide varistors (MOVs) or RC snubbers across inductive AC field devices (such as solenoid valves and relay coils) to suppress voltage transients during switching.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield \u0026amp; Earth Grounding:\u003c\/strong\u003e Secure all field cable shielding and baseplate mounting brackets directly to the enclosure master ground bus to mitigate electromagnetic noise coupling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43684037623898,"sku":"IC693MDL340","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC693MDL340.png?v=1784601562","url":"https:\/\/www.spareoil.com\/ar\/products\/ic693mdl340-series-90-30-discrete-output-module-ge-fanuc","provider":"SpareOil Automation","version":"1.0","type":"link"}