{"product_id":"ic693mdl940-ge-fanuc-series-90-30-relay-output-module","title":"IC693MDL940 | GE Fanuc | Series 90-30 Relay Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE IC693MDL940\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC693MDL940\u003c\/strong\u003e Relay Output Module, operates as a dedicated hardware component for switching AC and DC load circuits within Series 90-30 backplane platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693MDL940\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.37 kg (0.81 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSingle-slot Series 90-30 module format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard Series 90-30 backplane supply current draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Points\u003c\/td\u003e\n\u003ctd\u003e16 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Grouping\u003c\/td\u003e\n\u003ctd\u003e4 isolated groups (4 outputs per group)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC \/ 120\/240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e5 to 30 VDC \/ 5 to 250 VAC (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Load Current per Output\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Load Current per Common\u003c\/td\u003e\n\u003ctd\u003e4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin Load Current\u003c\/td\u003e\n\u003ctd\u003e10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inrush Current\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e15 ms max (ON and OFF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Output Execution\u003c\/h3\u003e\n\u003cp\u003eThe module processes discrete output logic transmitted across the backplane bus to drive electromechanical relay contacts. System-level backplane bus communication velocity supports cycle updating to synchronize all 16 channels. High I\/O density scaling allows 4 independent common groups, providing electrical isolation for mixed-voltage field loads. Onboard status LEDs provide real-time logic execution feedback for local diagnostics.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the maximum continuous current ratings per point and per common group? A: Each individual relay output channel supports up to 2 A, while each 4-point common group allows a maximum continuous load of 4 A.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum switching response time for the relay contacts? A: The physical contact actuation response time is 15 ms maximum for both ON and OFF transitions.\u003c\/p\u003e\n\u003cp\u003eQ: What voltage ranges can be controlled using the IC693MDL940 output points? A: The relay contacts handle operating voltages ranging from 5 to 30 VDC for direct current loads, and 5 to 250 VAC (50\/60 Hz) for alternating current loads.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaseplate Insertion:\u003c\/strong\u003e Disconnect rack power before inserting or removing the module from the Series 90-30 baseplate to avoid arcing on backplane connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring Configuration:\u003c\/strong\u003e Connect field power lines to the designated common terminals for each of the 4 independent groups. Ensure current per common does not exceed 4 A continuous load.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductive Load Suppression:\u003c\/strong\u003e Install external RC snubbers across AC inductive loads or flyback diodes across DC inductive loads to protect mechanical relay contacts from voltage spikes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield \u0026amp; Earth Grounding:\u003c\/strong\u003e Connect all cable shields and enclosure ground points directly to the master earth bus to prevent electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43684107911258,"sku":"IC693MDL940","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC693MDL940.png?v=1784605789","url":"https:\/\/www.spareoil.com\/ar\/products\/ic693mdl940-ge-fanuc-series-90-30-relay-output-module","provider":"SpareOil Automation","version":"1.0","type":"link"}