{"product_id":"ic694alg232-ge-rx3i-pacsystem-analog-voltage-input-module","title":"IC694ALG232 | GE | RX3i PACSystem Analog Voltage Input Module","description":"\u003cp\u003eConfigured for high-density voltage processing in RX3i PACSystem platforms, the \u003cstrong\u003eGE IC694ALG232\u003c\/strong\u003e (\u003cstrong\u003eIC694ALG232\u003c\/strong\u003e Analog Voltage Input Module) provides direct physical\/electrical execution. The module interfaces analog field signals through 16 single-ended or 8 differential input channels, applying a 16-bit analog-to-digital converter for high-resolution signal digitization across the backplane network.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC694ALG232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eRX3i PACSystem\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Voltage Input Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 single-ended or 8 differential\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit A\/D conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e112 mA at 5 VDC; 110 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eLED indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Altitude\u003c\/td\u003e\n\u003ctd\u003e1000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSingle-slot RX3i baseplate footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.54 kg (10.00 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Interfacing and Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe IC694ALG232 interfaces with the RX3i system backplane to transfer digitized 16-bit input words directly to controller memory registers. The module leverages backplane bus communication velocity to maintain real-time throughput across all active single-ended or differential channel groupings. Integrated firmware flash compatibility ensures synchronized operational timing and consistent scan execution when scaling I\/O density across multi-rack RX3i expansion architectures.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What power rails are required to operate the IC694ALG232 module?\u003c\/p\u003e\n\u003cp\u003eA: The module draws 112 mA from the internal 5 VDC backplane supply and 110 mA from the 24 VDC system power rail.\u003c\/p\u003e\n\u003cp\u003eQ: How can the channel architecture of the module be wired?\u003c\/p\u003e\n\u003cp\u003eA: The hardware supports software-configurable physical field wiring for either 16 single-ended input channels or 8 differential input channels.\u003c\/p\u003e\n\u003cp\u003eQ: What environmental temperature range is supported during active operations?\u003c\/p\u003e\n\u003cp\u003eA: The module is rated for continuous operation within ambient temperatures ranging from 0 to 60 deg C.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDe-energize system rack power and external 24 VDC field supplies prior to inserting or removing the module from the baseplate slot.\u003c\/li\u003e\n\u003cli\u003eAttach an ESD grounding wrist strap to an unpainted earth-grounded metal surface on the enclosure enclosure before handling the unit.\u003c\/li\u003e\n\u003cli\u003eAlign the card housing with the RX3i baseplate slot guide rails and push firmly until the rear backplane connector fully seats.\u003c\/li\u003e\n\u003cli\u003eWire field input leads according to single-ended or differential channel terminal diagrams, landing cable shield drain wires at a single enclosure ground point.\u003c\/li\u003e\n\u003cli\u003eApply power and verify that the front-panel LED indicators show normal operational status without fault indications.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43787779637338,"sku":"IC694ALG232","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC694ALG233_f29557d5-724e-4c04-8284-fa50cb27b31d.png?v=1785921631","url":"https:\/\/www.spareoil.com\/ar\/products\/ic694alg232-ge-rx3i-pacsystem-analog-voltage-input-module","provider":"SpareOil Automation","version":"1.0","type":"link"}