{"product_id":"ic694apu300-ge-fanuc-rx3i-pacsystem-high-speed-counter-module","title":"IC694APU300 GE Fanuc RX3i PacSystem High-Speed Counter Module","description":"\u003cp\u003eConfigured for high-speed counting and measurement tasks in RX3i PacSystem platforms, the \u003cstrong\u003eGE Fanuc IC694APU300\u003c\/strong\u003e (\u003cstrong\u003eIC694APU300\u003c\/strong\u003e High-speed Counter Module) provides direct physical\/electrical execution. The hardware processes dynamic field-level frequency inputs and actuates localized positive logic outputs directly based on configured counter parameters.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIC694APU300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.37 kg (0.81 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard single-slot RX3i carrier footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 mA (1.25 Watts) from 5 VDC backplane bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Count Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 MHz (Duty cycle 25% to 87%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 single-ended inputs or 6 differential inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 VDC (TSEL jumpered to INCOM); 10 to 30 VDC (TSEL open)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOff-State Leakage Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 uA maximum per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFour positive logic outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.7 to 40 VDC @ 1.5 A maximum resistive load (0.5 A pilot duty)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage Drop\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 V @ 500 mA; 1.5 V @ 1.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGroup-to-group Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous; 1500 VAC transient for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe IC694APU300 utilizes direct backplane bus communication paths to transfer real-time counting registers and diagnostic data without requiring additional high-speed communication licences. The module optimizes overall system I\/O density scaling by executing internal counting processes locally on the card, preventing standard CPU backplane scan times from delaying rapid-switching pulse processing. Field logic configurations remain reliable because the module provides integrated electronic short-circuit protection (ESCP) with self-healing attributes, enabling automatic circuit recovery following overcurrent faults.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the IC694APU300 module handle standard CMOS loads directly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The discrete output channels on this high-speed counter module are equipped with direct CMOS load drive capabilities to interface with modern solid-state industrial logic circuits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the peak current threshold before the Electronic Short Circuit Protection (ESCP) trips?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The output channels are engineered to allow an inrush current of up to 1.6 A without triggering the active overcurrent ESCP protection circuit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How is the module protected against field wiring errors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The hardware incorporates dedicated reverse polarity protection to prevent damage to internal circuits if reverse wiring occurs between the OUTPWR and OUTCOM field terminals.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Mounting:\u003c\/strong\u003e Align the module rails with the designated RX3i system slot and insert the module firmly until the backplane connector locks into position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Configuration:\u003c\/strong\u003e When wiring 5 VDC nominal inputs, verify that the TSEL terminal is jumpered directly to the INCOM terminal. For signals between 10 VDC and 30 VDC, keep the TSEL terminal open.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Barriers:\u003c\/strong\u003e Maintain isolation integrity between different module groups by routing high-speed signal cables separate from high-power AC lines. The group-to-group rating is 250 VAC continuous.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding:\u003c\/strong\u003e Terminate high-speed encoder input shields directly to the chassis ground rail using low-impedance grounding clamps to minimize EMI-induced pulse distortion.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43668108345434,"sku":"IC694APU300","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC694APU300.png?v=1784259025","url":"https:\/\/www.spareoil.com\/ar\/products\/ic694apu300-ge-fanuc-rx3i-pacsystem-high-speed-counter-module","provider":"SpareOil Automation","version":"1.0","type":"link"}