{"product_id":"ic694cee001-pacsystems-rx3i-expansion-carrier-ge-fanuc","title":"IC694CEE001 PACSystems RX3i Expansion Carrier | GE Fanuc","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC694CEE001\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC694CEE001\u003c\/strong\u003e Expansion Carrier, operates as a dedicated hardware component for extending I\/O slot capacity within PACSystems RX3i platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC694CEE001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.56 lbs (0.26 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard RX3i expansion footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via host CEP001 carrier (24 VDC bus, 700 mA rated current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot Configuration\u003c\/td\u003e\n\u003ctd\u003e2 slots total (1 on CEP001 host + 1 on CEE001 expansion)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget Modules\u003c\/td\u003e\n\u003ctd\u003eIC694 I\/O modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd\u003ePROFINET I\/O LAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Data Capacity\u003c\/td\u003e\n\u003ctd\u003e1024 bytes maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Options\u003c\/td\u003e\n\u003ctd\u003eDIN Rail or Panel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet Deterministic Networks and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe IC694CEE001 expands local station backplane capacity by adding a secondary physical interface slot for IC694 modules while maintaining integration across Profinet deterministic networks. By routing power and data buses directly through the host CEP001 carrier, the assembly executes I\/O density scaling up to the 1024-byte system limit without requiring redundant external power drops or software reconfigurations. Backplane bus communication velocity and firmware flash compatibility remain synchronized across both carrier slots during real-time data transport.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is primary operating power supplied to the IC694CEE001 expansion carrier?\u003c\/p\u003e\n\u003cp\u003eA: The IC694CEE001 receives its internal operating power directly from the connected host CEP001 carrier module via the local backplane interface, drawing up to 700 mA at 24 VDC nominal.\u003c\/p\u003e\n\u003cp\u003eQ: Which module types are supported in the expansion slot of the IC694CEE001?\u003c\/p\u003e\n\u003cp\u003eA: The expansion slot on the IC694CEE001 is designed specifically to accept standard PACSystems RX3i IC694 series I\/O modules.\u003c\/p\u003e\n\u003cp\u003eQ: What environmental enclosure considerations apply to installing this module?\u003c\/p\u003e\n\u003cp\u003eA: The IC694CEE001 carries an IP20 ingress protection rating and must be installed inside a clean, dry control enclosure that provides protection against dust and moisture.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDe-energize power to the host CEP001 carrier and surrounding backplane hardware prior to mechanical installation.\u003c\/li\u003e\n\u003cli\u003eMount the IC694CEE001 carrier onto a standard 35 mm DIN rail or fasten securely to an enclosure panel using mechanical hardware.\u003c\/li\u003e\n\u003cli\u003eAlign and seat the inter-carrier backplane connector to establish physical and electrical continuity with the host CEP001 module.\u003c\/li\u003e\n\u003cli\u003eInsert the target IC694 I\/O module into the CEE001 expansion slot, ensuring terminal block wiring remains isolated from live bus voltage.\u003c\/li\u003e\n\u003cli\u003eVerify that all field wiring cable shields are grounded at the system earth ground bus to suppress electromagnetic noise before applying 24 VDC system power.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43778251915354,"sku":"IC694CEE001","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC694CEE0011.png?v=1785736957","url":"https:\/\/www.spareoil.com\/ar\/products\/ic694cee001-pacsystems-rx3i-expansion-carrier-ge-fanuc","provider":"SpareOil Automation","version":"1.0","type":"link"}