{"product_id":"ic694mdl240-ge-fanuc-pacsystem-rx3i-discrete-input-module","title":"IC694MDL240 GE Fanuc PACSystem RX3i Discrete Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC694MDL240\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC694MDL240\u003c\/strong\u003e Discrete Input Module, operates as a dedicated hardware component for high-voltage AC binary signal sensing within PACSystem RX3i platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC694MDL240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.26 kg (0.56 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSingle-slot RX3i module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e90 mA at 5 VDC from backplane bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003eSixteen (16) discrete input points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC (85 to 132 VAC input range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency Range\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channel Grouping\u003c\/td\u003e\n\u003ctd\u003eSingle group of 16 inputs with 1 common terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Voltage \/ Current\u003c\/td\u003e\n\u003ctd\u003e74 to 132 VAC; 6 mA (12 mA max per channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Voltage \/ Current\u003c\/td\u003e\n\u003ctd\u003e0 to 20 VAC; 2.2 mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Response Time\u003c\/td\u003e\n\u003ctd\u003eOn: 30 ms max; Off: 45 ms max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Rating\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous; 1500 VAC for 1 minute (optical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Display\u003c\/td\u003e\n\u003ctd\u003e16 green LED channel indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe IC694MDL240 interfaces directly with the PACSystem RX3i universal backplane bus, transferring 16 discrete signal states into CPU memory tables during each rack scan cycle. Supporting high I\/O density scaling across populated chassis slots, the module draws 90 mA from the internal +5 VDC logic bus while optical isolation barriers rated at 250 VAC continuous protect system electronics against external noise spikes. Firmware flash compatibility across the RX3i platform ensures proper module identification and diagnostic state reporting without controller intervention.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the backplane power supply requirements for the IC694MDL240 input module?\u003c\/p\u003e\n\u003cp\u003eA: The module draws a maximum current of 90 mA from the +5 VDC backplane bus when all 16 input channels are energized.\u003c\/p\u003e\n\u003cp\u003eQ: What are the On-state and Off-state voltage thresholds for signal detection?\u003c\/p\u003e\n\u003cp\u003eA: An input point detects an On state between 74 VAC and 132 VAC, while an Off state is guaranteed between 0 VAC and 20 VAC.\u003c\/p\u003e\n\u003cp\u003eQ: How are field wiring common connections structured across the 16 input points?\u003c\/p\u003e\n\u003cp\u003eA: All 16 discrete input channels on the module are wired in a single isolated group sharing one common terminal.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eTurn off all backplane power and field input source power prior to inserting or removing the module from the baseplate rack slot.\u003c\/li\u003e\n\u003cli\u003eAlign the module housing with the backplane slot guides and push firmly until the upper and lower latch levers lock into the chassis frame.\u003c\/li\u003e\n\u003cli\u003eRoute 120 VAC field input wiring separately from low-voltage DC communication lines to prevent induced electrical noise.\u003c\/li\u003e\n\u003cli\u003eVerify that the field supply common line is connected securely to the module's single common terminal before applying power.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43725362724954,"sku":"IC694MDL240","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC694MDL240.png?v=1784886254","url":"https:\/\/www.spareoil.com\/ar\/products\/ic694mdl240-ge-fanuc-pacsystem-rx3i-discrete-input-module","provider":"SpareOil Automation","version":"1.0","type":"link"}