{"product_id":"ic694tbb132-ge-fanuc-pacsystem-rx3i-terminal-block","title":"IC694TBB132 GE Fanuc PACSystem RX3i Terminal Block","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC694TBB132\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC694TBB132\u003c\/strong\u003e Terminal Block, operates as a dedicated hardware component for high-density field wiring termination within PACSystem RX3i platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC694TBB132\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.17 kg (0.38 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eExtended box style matching standard RX3i\/Series 90-30 depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive physical termination component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Count\u003c\/td\u003e\n\u003ctd\u003e36 positions (32 active terminals)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003eScrew-type terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening Torque\u003c\/td\u003e\n\u003ctd\u003e7 lb-in (0.8 Nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Range\u003c\/td\u003e\n\u003ctd\u003e#14 to #26 AWG solid or stranded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Strip Length\u003c\/td\u003e\n\u003ctd\u003e7.87 mm (0.310 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemovability\u003c\/td\u003e\n\u003ctd\u003eRemovable and insertable under power (RIUP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemoval Detection\u003c\/td\u003e\n\u003ctd\u003eModule-based signal detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Modules\u003c\/td\u003e\n\u003ctd\u003eRX3i and Series 90-30 High-Density and 16-channel isolated I\/O modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eI\/O Density Scaling \u0026amp; Hardware System Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe IC694TBB132 extended box terminal assembly is constructed to facilitate I\/O density scaling across high-density 36-pin module interfaces. Providing 36 terminal positions for up to 32 discrete field signal channels, the unit maintains mechanical alignment with both PACSystem RX3i and legacy Series 90-30 high-density I\/O modules. Integrated removal-detection keys allow seamless swap operations with full support for removal and insertion under power (RIUP), preventing disruption to backplane bus communication velocity across adjacent active chassis slots.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What wire gauge size and strip length are specified for the IC694TBB132 terminal connections?\u003c\/p\u003e\n\u003cp\u003eA: The terminal block accepts #14 to #26 AWG solid or stranded conductors stripped to a length of 7.87 mm (0.310 in).\u003c\/p\u003e\n\u003cp\u003eQ: Does the IC694TBB132 terminal block support removal and insertion under power (RIUP)?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the removable terminal block supports RIUP execution when paired with compatible RX3i high-density I\/O modules.\u003c\/p\u003e\n\u003cp\u003eQ: What torque setting should be applied to the terminal screws during installation?\u003c\/p\u003e\n\u003cp\u003eA: Terminal screws must be tightened to a nominal torque of 7 lb-in (0.8 Nm) to ensure proper conductor retention and low contact resistance.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eStrip conductor insulation to exactly 7.87 mm (0.310 in) before inserting wires into the screw terminal positions.\u003c\/li\u003e\n\u003cli\u003eTighten terminal connection screws using a calibrated torque screwdriver set to 7 lb-in to prevent wire damage or loose connections.\u003c\/li\u003e\n\u003cli\u003eAlign the terminal block assembly with the front connector header of the target high-density RX3i or Series 90-30 module and press firmly until side latches snap into place.\u003c\/li\u003e\n\u003cli\u003eRoute field wiring harnesses neatly through the lower wiring duct, keeping signal conductors isolated from high-voltage AC lines.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43725311017050,"sku":"IC694TBB132","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC694TBB132.png?v=1784885428","url":"https:\/\/www.spareoil.com\/ar\/products\/ic694tbb132-ge-fanuc-pacsystem-rx3i-terminal-block","provider":"SpareOil Automation","version":"1.0","type":"link"}