{"product_id":"ic695alg608-ge-fanuc-pacsystem-rx3i-analog-input-module","title":"IC695ALG608 GE Fanuc PACSystem RX3i Analog Input Module","description":"\u003cp\u003eConfigured for analog signal digitizing in PACSystem RX3i platforms, the \u003cstrong\u003eGE Fanuc IC695ALG608\u003c\/strong\u003e (\u003cstrong\u003eIC695ALG608\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC695ALG608\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.31 kg (0.69 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard RX3i single-slot module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e330 mA max at 5.0 VDC, 600 mA max at 3.3 VDC (4.83 W total dissipation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e8 non-isolated single-ended or 4 non-isolated differential\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Ranges (Voltage)\u003c\/td\u003e\n\u003ctd\u003e+\/-10 VDC, 0-10 VDC, +\/-5 VDC, 0-5 VDC, 1-5 VDC, +\/-50 mV, +\/-150 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Ranges (Current)\u003c\/td\u003e\n\u003ctd\u003e0-20 mA, 4-20 mA, +\/-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eADC Resolution\u003c\/td\u003e\n\u003ctd\u003e24-bit converter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Format\u003c\/td\u003e\n\u003ctd\u003eConfigurable IEEE 32-bit floating point or 16-bit integer in 32-bit field\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfigurable Filters\u003c\/td\u003e\n\u003ctd\u003e8 Hz, 12 Hz, 16 Hz, 40 Hz, 200 Hz, 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;100 kohms (Voltage), 249 ohms +\/-1% (Current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage \/ Overcurrent Protection\u003c\/td\u003e\n\u003ctd\u003e+\/-60 VDC continuous (Voltage), +\/-28 mA continuous (Current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Terminal Blocks\u003c\/td\u003e\n\u003ctd\u003eIC694TBB032, IC694TBB132, IC694TBS032, IC694TBS132\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Firmware Integrity\u003c\/h3\u003e\n\u003cp\u003eThe IC695ALG608 transfers converted 24-bit analog data over the PCI-based RX3i backplane, maintaining fast bus communication velocity for real-time control routines. Firmware flash compatibility via Proficy Machine Edition (version 5.0 SP3 or later) enables soft configuration of per-channel ranges, scaling limits, and digital filtering options without physical jumper alterations. Built-in autocalibration routines execute on power-up to ensure accurate conversion thresholds across all active channels.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What power rails does the IC695ALG608 draw from the RX3i backplane bus?\u003c\/p\u003e\n\u003cp\u003eA: The module draws power directly from both the 3.3 VDC rail (up to 600 mA) and the 5.0 VDC rail (up to 330 mA), with a total maximum power dissipation of 4.83 W.\u003c\/p\u003e\n\u003cp\u003eQ: How are open-circuit conditions handled on current input loops?\u003c\/p\u003e\n\u003cp\u003eA: When configured for 4-20 mA or 1-5 VDC ranges, the module performs open-circuit detection with a maximum response time of 1 second, flagging diagnostic status bits in CPU memory.\u003c\/p\u003e\n\u003cp\u003eQ: Can single-ended and differential configurations be mixed on the same module?\u003c\/p\u003e\n\u003cp\u003eA: The module operates either as an 8-channel single-ended array or a 4-channel differential array based on hardware wiring and module software configuration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower down the RX3i backplane before installing or removing the IC695ALG608 module to avoid backplane pin erosion or CPU fault generation.\u003c\/li\u003e\n\u003cli\u003eSeat the module firmly into its designated RX3i slot and ensure the retaining levers lock into place on the baseplate.\u003c\/li\u003e\n\u003cli\u003eTerminate shielded twisted-pair cables using standard grounding practices, bonding the cable shield to the ground bar near the terminal block to reject high-frequency electrical noise.\u003c\/li\u003e\n\u003cli\u003eVerify that current loops do not exceed the +\/-28 mA continuous limit and voltage lines stay within the +\/-60 VDC continuous overvoltage rating.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43724880871514,"sku":"IC695ALG608","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC695ALG608.jpg?v=1784881034","url":"https:\/\/www.spareoil.com\/ar\/products\/ic695alg608-ge-fanuc-pacsystem-rx3i-analog-input-module","provider":"SpareOil Automation","version":"1.0","type":"link"}