{"product_id":"ic695alg626-ge-fanuc-pacsystems-rx3i-analog-input-module","title":"IC695ALG626 GE Fanuc PACSystems RX3i Analog Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC695ALG626\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC695ALG626\u003c\/strong\u003e Non-isolated Analog Input Module, operates as a dedicated hardware component for multi-channel voltage\/current signal processing and HART transducer communication within PACSystems RX3i platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC695ALG626\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.63 lbs (0.28 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSingle-slot PACSystems RX3i module width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C (32 to 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e600 mA at 3.3 VDC; 450 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channel Count\u003c\/td\u003e\n\u003ctd\u003e16 single-ended or 8 differential channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Signal Ranges\u003c\/td\u003e\n\u003ctd\u003e0 to 20 mA, 4 to 20 mA, +\/-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Signal Ranges\u003c\/td\u003e\n\u003ctd\u003e+\/-10 VDC, 0 to 10 VDC, +\/-5 VDC, 0 to 5 VDC, 1 to 5 VDC, +\/-50 mV, +\/-150 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Resolution\u003c\/td\u003e\n\u003ctd\u003e24-bit ADC converted to floating point IEEE 32-bit or 16-bit integer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Input Resistance\u003c\/td\u003e\n\u003ctd\u003e249 ohms +\/-1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;100 kohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfigurable Input Filters\u003c\/td\u003e\n\u003ctd\u003e8 Hz, 12 Hz, 16 Hz, 40 Hz, 200 Hz, 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Protocol Support\u003c\/td\u003e\n\u003ctd\u003eHART Version 5.0 with 4 internal HART modems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Limits\u003c\/td\u003e\n\u003ctd\u003eContinuous overvoltage: +\/-60 VDC; Continuous overcurrent: +\/-28 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe IC695ALG626 enhances backplane bus communication velocity across the PACSystems RX3i universal backplane by executing 24-bit analog-to-digital conversions directly into 32-bit floating point or integer memory structures. Configured for I\/O density scaling, the single-slot footprint provides up to 16 single-ended or 8 differential input channels alongside 4 embedded HART modems for digital pass-through data acquisition. Module parameters feature full software configuration without jumpers, while onboard firmware flash compatibility supports startup autocalibration, open circuit fault detection, and real-time high\/low limit alarms.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What power rails are drawn from the RX3i backplane by the IC695ALG626?\u003c\/p\u003e\n\u003cp\u003eA: The module draws 600 mA from the internal 3.3 VDC bus rail and 450 mA from the internal 5 VDC bus rail.\u003c\/p\u003e\n\u003cp\u003eQ: Does the IC695ALG626 support hot-swapping on the PACSystems RX3i backplane?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the hardware supports insertion and removal under power (hot-swapping) when installed in a PACSystems RX3i universal backplane.\u003c\/p\u003e\n\u003cp\u003eQ: What specific input range is required when utilizing HART communication?\u003c\/p\u003e\n\u003cp\u003eA: Channels utilizing HART Version 5.0 digital communications must be software-configured for the 4 to 20 mA current range.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerify that the target rack location is on a PACSystems RX3i universal backplane prior to inserting the module.\u003c\/li\u003e\n\u003cli\u003eAlign the module housing with the backplane guide slots and press firmly until the backplane bus connector fully engages.\u003c\/li\u003e\n\u003cli\u003eWire field transmitters to the removable terminal block (TB), maintaining isolated signal paths for 4-20 mA HART loop protocol connections.\u003c\/li\u003e\n\u003cli\u003eAttach the removable terminal block to the front of the module, ensuring the terminal block detector latches completely to activate field-side status logic.\u003c\/li\u003e\n\u003cli\u003eRoute low-level analog wiring in dedicated raceways separated from power cables, connecting cable shielding at a single grounding terminal.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43738147225690,"sku":"IC695ALG626","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC695ALG626.png?v=1785133856","url":"https:\/\/www.spareoil.com\/ar\/products\/ic695alg626-ge-fanuc-pacsystems-rx3i-analog-input-module","provider":"SpareOil Automation","version":"1.0","type":"link"}