{"product_id":"ic697alg320-ge-series-90-70-analog-output-module","title":"IC697ALG320 | GE |Series 90-70 Analog Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE IC697ALG320\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC697ALG320\u003c\/strong\u003e Analog Output Module, operates as a dedicated hardware component for digital-to-analog signal conversion within Series 90-70 platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC697ALG320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.00 lbs (0.91 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSingle-slot baseplate form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e8.3 W maximum (1.66 A at 5 VDC from backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e4 individually configured outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Output Range\u003c\/td\u003e\n\u003ctd\u003e-10 VDC to +10 VDC (bipolar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Output Range\u003c\/td\u003e\n\u003ctd\u003e0-20 mA, 4-20 mA (default), 0 to 22.2 mA max range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDAC Resolution\u003c\/td\u003e\n\u003ctd\u003e16-bit resolution (14-bit monotonicity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSequential Update Rate\u003c\/td\u003e\n\u003ctd\u003e2.0 ms for all 4 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal User Power\u003c\/td\u003e\n\u003ctd\u003e150 mA at 24 VDC nominal (10 to 30 VDC range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Temperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e25 ppm per deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Temperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e50 ppm per deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Data Storage\u003c\/td\u003e\n\u003ctd\u003eNon-volatile onboard EEPROM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe module executes synchronous data mapping across the Series 90-70 backplane, matching high-speed CPU sweep intervals to achieve a 2.0 ms total channel update cycle. Onboard configuration parameters, user scaling matrices, and diagnostic logic interact directly with the main processor register assembly. The non-volatile EEPROM safeguards factory calibration offsets and firmware flash compatibility frameworks against backplane power loss conditions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the specific electrical load limitations for the analog outputs?\u003c\/p\u003e\n\u003cp\u003eA: When configured for voltage operations, the channel requires a minimum resistive load of 2000 ohms and a maximum capacitive load of 1000 picofarad. For current operations, the loops support resistive loads up to 700 ohms, capacitive loads up to 1.0 microfarad, and inductive loads up to 250 milliHenry.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle short circuits or field wiring faults?\u003c\/p\u003e\n\u003cp\u003eA: The voltage and current loops are designed with continuous short-circuit protection. Upon physical resolution of the field fault or shorted line, the affected circuit automatically recovers and returns to its normal calibrated operating execution state without requiring a hardware or rack reset.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum physical module density per baseplate?\u003c\/p\u003e\n\u003cp\u003eA: System architecture rules permit a maximum configuration of 7 modules inside a primary CPU rack and up to 8 modules within a standard expansion rack baseplate, enabling a scalable density up to 252 discrete output channels.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaseplate Insertion\u003c\/strong\u003e: Verify that rack power is completely disconnected. Slide the module into a single open slot of a 5-slot or 10-slot baseplate, ensuring correct alignment with the backplane connectors before fully seating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring and Power\u003c\/strong\u003e: Wire the external 24 VDC field side power supply to the designated terminals to enable the 4-20 mA current loops. Run analog signal lines using individual twisted-shielded pairs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding\u003c\/strong\u003e: Terminate all signal shields at the designated chassis ground bar inside the enclosure. Maintain strict physical separation between low-voltage analog cables and high-voltage AC power lines to minimize induced transient interference.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43616515850330,"sku":"IC697ALG320","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC697ALG320.png?v=1783481145","url":"https:\/\/www.spareoil.com\/ar\/products\/ic697alg320-ge-series-90-70-analog-output-module","provider":"SpareOil Automation","version":"1.0","type":"link"}