{"product_id":"ic697bem742-ge-series-90-70-bus-controller","title":"IC697BEM742 GE Series 90-70 Bus Controller","description":"\u003cp\u003eThe \u003cstrong\u003eGE IC697BEM742\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC697BEM742\u003c\/strong\u003e Bus Controller, operates as a dedicated hardware component for multi-channel redundant bus management and data routing within Series 90-70 backplane architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC697BEM742\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.57 kg (1.25 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSingle-slot Series 90-70 module format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard Series 90-70 backplane bus power draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRAM Memory\u003c\/td\u003e\n\u003ctd\u003e2 Megabytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlash Memory\u003c\/td\u003e\n\u003ctd\u003e2 Megabytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transmission Rate\u003c\/td\u003e\n\u003ctd\u003e1 Mbit\/second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Channels\u003c\/td\u003e\n\u003ctd\u003eDual channels for redundant bus operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indication\u003c\/td\u003e\n\u003ctd\u003eFront-panel LED indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Network Integrity\u003c\/h3\u003e\n\u003cp\u003eThe controller executes deterministically across the backplane bus, supporting high-speed backplane bus communication velocity and continuous data interchange between the host CPU and distributed sub-networks. Flash memory compatibility allows seamless firmware execution and user configuration storage, while I\/O density scaling and dual-channel bus architecture ensure failover operation without interrupting control tasks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What data transmission rate is supported across the dual bus channels?\u003c\/p\u003e\n\u003cp\u003eA: The module supports transmission speeds of up to 1 Mbit\/second across both integrated bus channels.\u003c\/p\u003e\n\u003cp\u003eQ: How many backplane slots are required to install the IC697BEM742 module?\u003c\/p\u003e\n\u003cp\u003eA: The module is designed in a standard single-slot Series 90-70 form factor and occupies one slot on the backplane baseplate.\u003c\/p\u003e\n\u003cp\u003eQ: What memory capacity is provided on the module for runtime operations and storage?\u003c\/p\u003e\n\u003cp\u003eA: The module features 2 Megabytes of integrated RAM for active execution alongside 2 Megabytes of onboard Flash memory for non-volatile storage.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaseplate Installation:\u003c\/strong\u003e De-energize system power before sliding the module into its designated slot on the Series 90-70 rack, ensuring edge connector contacts lock firmly into the backplane bus socket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Channel Wiring:\u003c\/strong\u003e Connect external communication cables to the primary and secondary bus channel ports, maintaining strict port identification for dual-channel redundant networks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding:\u003c\/strong\u003e Attach cable shield drain wires directly to the master enclosure earthing terminal to reduce high-frequency electrical noise and transient interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental \u0026amp; Elevation Limits:\u003c\/strong\u003e Ensure the control cabinet is installed at an altitude below 1000 meters and maintains ambient temperatures between 0 and 60 deg C during active operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43684065509466,"sku":"IC697BEM742","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC697BEM742.png?v=1784602258","url":"https:\/\/www.spareoil.com\/ar\/products\/ic697bem742-ge-series-90-70-bus-controller","provider":"SpareOil Automation","version":"1.0","type":"link"}