{"product_id":"ic697cpu780-ge-fanuc-series-90-70-cpu-module","title":"IC697CPU780 GE Fanuc Series 90-70 CPU Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC697CPU780\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC697CPU780\u003c\/strong\u003e CPU module, operates as a dedicated hardware component for processing control logic and executing deterministic synchronization within Series 90-70 Programmable Logic Controller platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC697CPU780\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.00 lbs (0.45 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSingle-slot VME form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 - 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.6 Amps at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMicroprocessor\u003c\/td\u003e\n\u003ctd\u003e80386DX (16 MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoolean Execution Speed\u003c\/td\u003e\n\u003ctd\u003e0.4 microseconds per function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e12 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e8 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum System Memory\u003c\/td\u003e\n\u003ctd\u003e512 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Communication\u003c\/td\u003e\n\u003ctd\u003eRS485 interface via 15-pin D-connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Backup\u003c\/td\u003e\n\u003ctd\u003eIC697ACC701 Lithium (6 months data retention)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Standard\u003c\/td\u003e\n\u003ctd\u003eVME standard C.1 compliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFirmware Flash Compatibility and Redundant Execution\u003c\/h3\u003e\n\u003cp\u003eThe hardware utilizes a 16 MHz internal clock structure to manage high-speed data exchanges across the VME backplane. In redundant configurations, firmware flash compatibility between the primary and secondary units is required to maintain the 20 milliseconds scan extension limit. A firmware mismatch halts execution and prevents the one-scan bumpless transfer sequence when a transition from RUN to STOP mode occurs.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the exact operational current load drawn by the module from the backplane?\u003c\/p\u003e\n\u003cp\u003eA: The module draws a constant load of 1.6 Amps from the 5 VDC backplane power rail. Power supply sizing calculations for rack 0 must account for this baseline draw alongside any adjacent bus transmitter or redundancy communication modules.\u003c\/p\u003e\n\u003cp\u003eQ: How is the non-volatile memory protected during an extended power outage?\u003c\/p\u003e\n\u003cp\u003eA: The system memory retains data for up to six months using the IC697ACC701 lithium battery connected to the module front face. If the battery voltage drops below the critical threshold, the \"Module OK\" LED status transitions to indicate a memory backup fault.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Restrictions:\u003c\/strong\u003e The module must be installed exclusively in slot 1 of rack 0 within the Series 90-70 chassis to establish mastership over the VME backplane standard C.1 communications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Communication Link:\u003c\/strong\u003e When deploying a hot-standby pair, verify that the dedicated bus transmitter modules and redundancy cards are fully seated and anchored before powering up either CPU node.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Connection:\u003c\/strong\u003e Ensure the IC697ACC701 battery lead is securely plugged into the internal board connector prior to sliding the chassis into the frame to avoid memory parity errors on initial boot.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43627120787546,"sku":"IC697CPU780","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC697CPU780.png?v=1783654933","url":"https:\/\/www.spareoil.com\/ar\/products\/ic697cpu780-ge-fanuc-series-90-70-cpu-module","provider":"SpareOil Automation","version":"1.0","type":"link"}