{"product_id":"input-card-for-dcs-temperature-monitoring-yokogawa-cr5-pa-a-rtd","title":"Input Card for DCS Temperature Monitoring Yokogawa CR5-PA*A RTD","description":"\u003ch2\u003eYokogawa CR5-PA*A RTD Input Card\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-precision temperature acquisition in Yokogawa distributed control systems, the \u003cstrong\u003eYokogawa CR5-PA*A\u003c\/strong\u003e (\u003cstrong\u003eCR5-PA*A\u003c\/strong\u003e RTD Input Card) provides direct electrical execution of Pt100 resistance-to-digital signal conversion.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCR5-PA*A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 to 1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e120 × 90 × 115 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMax 12 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003ePt100 RTD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.03 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Connectivity and Signal Conditioning\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eCR5-PA*A\u003c\/strong\u003e module facilitates integration with the CENTUM CS3000 platform by providing multi-channel RTD input processing. The architecture incorporates channel-to-channel isolation to suppress common-mode noise and prevent ground potential differences from affecting the measurement accuracy of the Pt100 elements. To further maintain process stability, the module performs cold junction compensation (CJC) for integrated thermocouple referencing when required, though its primary function is optimized for resistive sensor inputs.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can this module be installed or removed while the I\/O nest is powered?\u003c\/p\u003e\n\u003cp\u003eA: No, the module does not support hot-swapping. Operators must isolate the 24 VDC power supply and disconnect field wiring from the module terminals before performing physical maintenance or replacement to avoid electrical damage to the backplane.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle signal interference on the RTD leads?\u003c\/p\u003e\n\u003cp\u003eA: The module utilizes dedicated input filtering and galvanic isolation to mitigate electromagnetic interference. For optimal performance in high-noise environments, use shielded 3-wire or 4-wire RTD cabling and terminate the shield at the cabinet entry point.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the module onto a standard DIN rail within the I\/O cabinet. Ensure the mounting orientation allows for adequate natural convection, as the unit dissipates up to 12 W under full load.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the chassis ground terminal of the module to the cabinet PE bus using a low-impedance copper strap to maintain the integrity of the galvanic isolation barrier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Route RTD signal cables through dedicated conduits, maintaining a physical separation of at least 200 mm from high-voltage AC lines or VFD output cables to minimize inductive crosstalk.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Utilize the DCS engineering station to verify the channel scaling and resistance mapping (JIS 1989 standard) before commissioning the loop to ensure correct process variable values are reported.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43627063902298,"sku":"CR5-PA*A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/500._f7796a46-5d1d-48d4-b480-7d8c41d67ab8.jpg?v=1783652317","url":"https:\/\/www.spareoil.com\/ar\/products\/input-card-for-dcs-temperature-monitoring-yokogawa-cr5-pa-a-rtd","provider":"SpareOil Automation","version":"1.0","type":"link"}