{"product_id":"muda-yokogawa-centum-vp-prosafe-rs-terminal-board","title":"MUDA Yokogawa CENTUM VP ProSafe-RS Terminal Board","description":"\u003ch2\u003eYokogawa MUD*A CENTUM VP Terminal Board\u003c\/h2\u003e\n\u003cp\u003eConfigured for specific technical task execution in CENTUM VP, ProSafe-RS, and SCADA architectures, the \u003cstrong\u003eYokogawa MUD*A\u003c\/strong\u003e (\u003cstrong\u003eYokogawa MUD*A\u003c\/strong\u003e Terminal Board) provides direct physical\/electrical execution of field signal termination routing. The unit manages analog, digital, and thermocouple wiring loops before routing signals directly to matching internal system input modules.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMUD*A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e100 x 75 x 25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive component (negligible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Terminals\u003c\/td\u003e\n\u003ctd\u003e32 screw-type terminals (up to 64 wire points)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Gauge Compatibility\u003c\/td\u003e\n\u003ctd\u003e24 AWG to 14 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003eUp to 3 A per terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003eUp to 250 VAC\/VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003eMinimum 100 MΩ at 500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstand Voltage\u003c\/td\u003e\n\u003ctd\u003e500 VAC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Integration \u0026amp; Signal Isolation\u003c\/h3\u003e\n\u003cp\u003eThe interface board processes diverse external electrical paths using built-in channel-to-channel isolation matrices to eliminate ground differentials. The copper trace routing maintains strict 4-20 mA HART loop protocol signal transparency, permitting high-frequency digital communication to pass onto the host distributed control system. For mixed temperature loops, integrated cold junction compensation (CJC) circuits generate continuous reference adjustments, ensuring precision measurement stability for connected thermocouple sensors.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can an engineer swap this board while the active control loops are energized? A: The hardware does not support hot-swap insertion or extraction under load. Operational safety constraints demand that technicians fully de-energize all connected 250 VAC\/VDC field lines before performing any replacement or maintenance activities.\u003c\/p\u003e\n\u003cp\u003eQ: How does the assembly handle mechanical energy in close proximity to rotating machinery? A: The physical chassis structure passes independent type testing for shock and vibration, withstanding peak displacements of 0.5 mm P-P across 0 to 14 Hz frequencies and shock decelerations up to 5 g for 11 ms durations.\u003c\/p\u003e\n\u003cp\u003eQ: Is a battery configuration necessary to maintain active configuration loops during power failure? A: The hardware operates as a purely passive distribution network requiring zero continuous operational current. All calibration parameters and reference thresholds depend entirely on the host distributed control system memory.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eChassis Fastening: Anchor the module structure onto standard symmetric DIN rails or bolt it securely onto the back panel layout of the cabinet enclosure. Confirm all tracking clips click firmly to establish structural integrity.\u003c\/li\u003e\n\u003cli\u003eSignal Separation: Run analog, digital, and thermocouple sensor field cabling in isolated conduit groups. Maintain physical distance thresholds between high-voltage power distribution conduits and low-level analog cables to minimize cross-talk risks.\u003c\/li\u003e\n\u003cli\u003eGround Earth Connection: Connect all external braided cable shields directly to the designated functional earth bar of the cabinet housing. Ensure the common ground pathway exhibits less than 1 ohm impedance to avoid high-frequency electrical interference.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43767828971610,"sku":"MUD*A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/693..jpg?v=1785464427","url":"https:\/\/www.spareoil.com\/ar\/products\/muda-yokogawa-centum-vp-prosafe-rs-terminal-board","provider":"SpareOil Automation","version":"1.0","type":"link"}